G3NA-610B AC100-240 Omron, G3NA-610B AC100-240 Datasheet - Page 2

SSR 600VAC 10A AC 100-240V

G3NA-610B AC100-240

Manufacturer Part Number
G3NA-610B AC100-240
Description
SSR 600VAC 10A AC 100-240V
Manufacturer
Omron
Series
G3NAr
Datasheet

Specifications of G3NA-610B AC100-240

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
10A
Voltage - Input
100 ~ 240VAC
Voltage - Load
360 ~ 660 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
100 VAC to 240 VAC
Load Current Rating
10 A
Contact Form
1 Form A
Relay Type
General Purpose Hockey Puck
Input Type
AC
Input Voltage (max)
264V
Output Voltage (max)
660V
Input Current (max)
7mA
Output Current
10A
Output Device
Triac
Pin Count
4
Mounting
Screw
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Compliant
Other names
G3NA-610BAC100-240
G3NA610BAC100240
Specifications
■ Ratings
Input (at an Ambient Temperature of 25°C)
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 240 VAC,
Output
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data.
■ Characteristics
468
G3NA-6@@B
G3NA-610B
G3NA-625B
G3NA-650B
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Model
2. Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data for further details.
2. When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.
Model
the input impedance is measured at 240 VAC).
Item
Solid State Relays (600 VAC Models)
400 to 600 VAC
5 to 24 VDC
100 to 240 VAC
Rated load voltage
Rated voltage
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1.8 V (RMS) max.
10 mA max. (at 400 VAC)
20 mA max. (at 600 VAC)
100 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Operating:−30°C to 80°C (with no icing or condensation)
Storage: −30°C to 100°C (with no icing or condensation)
Operating: 45% to 85%
Approx. 120 g
G3NA-610B-UTU
Operating voltage
4 to 32 VDC
75 to 264 VAC
360 to 660 VAC
Load voltage range
2
7 mA max.
72 kΩ±20%
G3NA-6
(See note 1.)
Impedance
0.5 to 10 A (at 40°C)
0.5 to 25 A (at 40°C)
0.5 to 50 A (at 40°C)
With heat sink
Applicable load
(See note 2.)
G3NA-625B-UTU
Load current (See note 1.)
4 VDC max.
75 VAC max.
Must operate voltage
0.5 to 4 A (at 40°C)
0.5 to 4 A (at 40°C)
0.5 to 6 A (at 40°C)
Without heat sink
Voltage level
1 VDC min.
20 VAC min.
G3NA-650B-UTU
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
Must release voltage
Inrush current