G9EA-1-B DC12 Omron, G9EA-1-B DC12 Datasheet - Page 4

DC POWER RELAY

G9EA-1-B DC12

Manufacturer Part Number
G9EA-1-B DC12
Description
DC POWER RELAY
Manufacturer
Omron
Series
G9EA-1r
Datasheet

Specifications of G9EA-1-B DC12

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
60A
Switching Voltage
400VDC - Max
Coil Type
Standard
Coil Current
417mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
0.96 VDC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
60A @ 400VDC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
0.96 VDC
Current, Rating
60 A
Dielectric Rating
2500 VAC
Dimensions
2.87 " L x 1.42 " W x 2.64 " H
Function
Power
Material, Contact
Ag Alloy
Standards
UL, CSA
Termination
Screw
Voltage, Control
12 VDC
Voltage, Drop, On-state
0.1 V (Max.)
Voltage, Rating
400 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G9EA-1-B-DC12
G9EA1B DC12
G9EA1BDC12
Z1610
■ All G9EA-1 Models
4
−10.0
10.0
− 2.0
− 4.0
− 6.0
− 8.0
30
25
20
15
10
8.0
6.0
4.0
2.0
0.0
5
0
Must-operate Voltage and
Must-release Voltage
Distributions
Characteristics were measured after applying vibration
at a frequency of 10 to 55 Hz (single amplitude of 0.75
mm) to the test piece (not energized) for 2 hours each
in 3 directions. The percentage rate of change is the
average value for all of the samples
Vibration Resistance
Start
Sample: G9EA-1
Number: 35
Sample: G9EA-1
Number: 5
20
DC Power Relays (60-A, 100-A Models)
40
Percentage of rated voltage (%)
Must-operate voltage
Must-release voltage
60
Must-release voltage
Must-operate voltage
80
After test
100
20
15
10
5
0
Shock Malfunction
Unit: m/s
Sample: G9EA-1
Number: 5
X
Z
The value at which malfunction occurred was
measured after applying shock to the test piece
3 times each in 6 directions along 3 axes.
Time Characteristic
Distributions
'
5.0
Deenergized
2
Sample: G9EA-1
Number: 35
10.0
G9EA-1
Y
Y
'
800
600
400
200
200
400
600
800
1,000
1,000
15.0
20.0
Y
'
Energized
Operate time
Release time
Y X
25.0
Time (ms)
Z
X
'
'
X
Z
Z
30.0
'
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
1
0
1
Sample: G9EA-1
Number: 5
−10.0
10.0
− 2.0
− 4.0
− 6.0
− 8.0
Vibration Malfunction
8.0
6.0
4.0
2.0
0.0
Characteristics were measured
of 490 m
along 3 axes
average value for all of the samples.
Shock Resistance
Start
Sample: G9EA-1
Number: 5
3
2
/s to the test piece 3 times each in 6 directions
5
. The percentage rate of change is the
10
Unconfirmed area
Confirmed area
Frequency (Hz)
30
Must-operate voltage
Must-release voltage
after applying a shock
50
100
After test

Related parts for G9EA-1-B DC12