H3CRA300AC100240DC100125 Omron, H3CRA300AC100240DC100125 Datasheet

SOLID STATE TIMER-ANALOG SET

H3CRA300AC100240DC100125

Manufacturer Part Number
H3CRA300AC100240DC100125
Description
SOLID STATE TIMER-ANALOG SET
Manufacturer
Omron

Specifications of H3CRA300AC100240DC100125

Lead Free Status / RoHS Status
Compliant
Multiple Operating Modes and Multiple Time
Ranges. DIN 48 x 48-mm Multifunctional
Timer with Wide AC/DC Power Supply Range
for Both High and Low Voltages.
• A wide AC/DC power supply range greatly reduces the number
• A wide range of applications with multiple operating modes, six
• Ecological design with reduced current consumption.
• Easy sequence checking with instantaneous outputs for a zero
• Length of 80 mm or less when panel-mounted with a P3GA-11
• PNP input models available.
• Standards: UL, CSA, NK, LR, EN 61812-1, and CE Marking.
Model Number Structure
■ Model Number Legend
Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 2 for avail-
1. Number of Pins
2. Input Type for 11-pin Models
3. Output
4. Suffix
5. Supply Voltage
H3CR-A@ @ @ - @ @
of timer models kept in stock.
modes for 11-pin models and four modes for 8-pin models.
set value.
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC)
Solid-state Multi-functional Timers
H3CR-A
None: 11-pin models
8:
None: No-voltage input (NPN type)
P:
None: Relay output (DPDT)
S:
E:
300: Dual mode models (signal ON/OFF-delay and one-shot)
301: Double time scale (range) models (0.1 s to 600 h)
100-240AC/100-125DC: 100 to 240 VAC/100 to 125 VDC
24-48AC/12-48DC:
24-48AC/DC:
ability.
8-pin models
Voltage input (PNP type)
Transistor output (NPN/PNP universal use)
Relay output (SPDT) with instantaneous relay output (SPDT)
1
2
3
4 5
24 to 48 VAC/12 to 48 VDC
24 to 48 VAC/VDC (Only for H3CR-A8E)
CSM_H3CR-A_DS_E_6_2
LR
1

Related parts for H3CRA300AC100240DC100125

H3CRA300AC100240DC100125 Summary of contents

Page 1

Solid-state Multi-functional Timers H3CR-A Multiple Operating Modes and Multiple Time Ranges. DIN 48 x 48-mm Multifunctional Timer with Wide AC/DC Power Supply Range for Both High and Low Voltages. • A wide AC/DC power supply range greatly reduces the number ...

Page 2

Ordering Information ■ List of Models Note: 1. Specify both the model number and supply voltage when ordering. Example: H3CR-A 100-240AC/100-125DC 2. The operating modes are as follows A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ...

Page 3

Accessories (Order Separately) Adapter, Protective Cover, Hold down Clip, Setting Ring and Panel Cover Name/specifications Flush Mounting Adapter Protective Cover Hold-down Clip (Sold in sets of For PF085A Socket two) For PL08 and PL11 Sockets Setting Ring A Setting ...

Page 4

Specifications ■ General Item H3CR-A/-AS Operating mode A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay (Only for H3CR-A-300) J: One-shot (Only for H3CR-A-300) Pin type 11-pin Input ...

Page 5

Ratings Rated supply voltage (See notes 1, 2, and 5.) 100 to 240 VAC (50/60 Hz)/100 to 125 VDC VAC (50/60 Hz)/ VDC ( VAC/VDC for H3CR- A8E) (See note3.) Operating voltage ...

Page 6

Characteristics ±0.2% FS max. (±0.2%±10 ms max range of 1 Accuracy of operating time ±5% FS ±50 ms (See note 1) Setting error Reset time Min. power-opening time: 0.1 s max. Min. pulse ...

Page 7

Connections ■ Block Diagrams H3CR-A/AS AC (DC) input Power supply circuit Reset input, start input, and gate input H3CR-AP AC (DC) input Power supply circuit Start Zero setting Time range/ Operating detection unit selectors mode selector circuit Oscillation Counting circuit ...

Page 8

H3CR-A8/A8S AC (DC) input Power supply circuit H3CR-A8E AC (DC) input Power supply circuit ■ I/O Functions Inputs (for -A/ Start Starts time-measurement. -AS models) Reset Interrupts time-measurement and resets time-measurement value. No time-measurement is made and control output is ...

Page 9

Terminal Arrangement Note: The delayed contact of conventional Timers was indicated as The contact symbol of the H3CR-A is indicated as 11-pin Models H3CR-A/-A-300/-A-301 (Contact Output) Power supply H3CR-AS (Transistor Output) Power supply Note: Terminals and ...

Page 10

Input Connections H3CR-A/-AS The inputs of the H3CR-A/-AS are no-voltage (short-circuit or open) inputs. No-voltage Inputs No-contact Input (Connection to NPN open collector output sensor VDC (sensor power supply power − supply Timer Sensor ...

Page 11

H3CR-AP The start input of the H3CR-AP is voltage input. (Voltage imposition or open) Voltage Inputs No-contact Input (Connection to PNP open collector output sensor VDC (sensor power supply power − supply Sensor Timer 10 ...

Page 12

Operation ■ Timing Chart Note: 1. The minimum power-opening time (“Rt” The minimum input pulse width (for start, reset The letter “t” in the timing charts stands for the set time and ...

Page 13

Operating mode D: Signal OFF- Power delay Start Reset Output relay (NC) Output relay (NO) (Output indicator) Power indicator E: Interval Power Start Reset Output relay (NC) Output relay (NO) (Output indicator) Power indicator G: Signal ON/ OFF-delay Power Start ...

Page 14

H3CR-A8/-A8S Operating mode A: ON-delay Power Output relay (NC) Output relay (NO) (output indicator) Power indicator Flicker ON start Power Output relay (NC) Output relay (NO) (output indicator) Power indicator E: Interval Power Output relay (NC) Output ...

Page 15

H3CR-A8E Operating mode A: ON-delay Power Output relay (NC) Output relay (NO) (output indicator) Instantaneous output relay (NC) Instantaneous output relay (NO) Power indicator Flicker ON start Power Output relay (NC) Output relay (NO) (output indicator) Instantaneous ...

Page 16

Dimensions Note: All units are in millimeters unless otherwise indicated. H3CR-A H3CR-AP H3CR-AS H3CR-A8 H3CR-A8S H3CR-A8E Dimensions with Set Ring Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ H3CR-A8@ H3CR-A H3CR-AS * 98.5 89.9 * 100.8 H3CR-AP * P2CF-11 P2CF-08 2.3 P2CF-11-E ...

Page 17

Application Examples (H3CR-A) A Mode: ON-delay ON-delay operation (A mode basic mode. 1. Power-ON Start/Power-OFF Reset The Power-ON start/Power-OFF reset operation is a standard operating method Power (2 and 10) Start (2 and 6) Reset (2 ...

Page 18

Signal Start/Signal Reset (in B Mode) If there is an abnormal signal, flashing starts. When the abnormal condition is restored, a reset signal stops the display flashing. Power (2 and 10) Start (2 and 6) Reset (2 and 7) ...

Page 19

Signal Start/Instantaneous Operation/ Time-limit Reset Power (2 and 10) Start (2 and 6) Control output and 11 and 4) Control output and 11 and 3) Power indicator Lit Start signal (NO ...

Page 20

Safety Precautions (H3CR-A) Refer to Safety Precautions for All Timers. Note: The following precautions apply to all H3CR-A models. ■ Power Supplies For the power supply of an input device of the H3CR-A@/-A@S/-AP, use an isolating transformer with the primary ...

Page 21

Relationship between Input and Power Supply Circuits (H3CR-A@/-A@S) An appropriate input is applied to the input signal terminals of the H3CR-A@/-A@S when one of the input terminals is short-circuited with the common terminal (terminal 2) for the input signals. Never ...

Page 22

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...