K8AB-PW2 Omron, K8AB-PW2 Datasheet - Page 2

3-phs Voltage Ry. 380-480VAC

K8AB-PW2

Manufacturer Part Number
K8AB-PW2
Description
3-phs Voltage Ry. 380-480VAC
Manufacturer
Omron
Series
K8ABr

Specifications of K8AB-PW2

Contact Form
SPDT
Coil Voltage
200 VAC to 500 VAC
Contact Rating
6 A at 250 VAC
Mounting Style
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K8A-BPW2
K8ABPW2
Z2807
Ratings and Specifications
2
Rated input voltage
Input load
Reversed phase and phase loss operating time
Reset method
Indicators
Output relays
Output relay ratings
Ambient operating temperature
Storage temperature
Ambient operating humidity
Storage humidity
Altitude
Terminal screw tightening torque
Terminal wiring method
Case color
Case material
Weight
Mounting
Dimensions
Ratings
Phase-sequence Phase-loss Relay
Three-phase, three-wire mode, 200 to 500 VAC
15 VA max.
0.1 s max.
Automatic reset
Power (PWR): Green, Relay output (RY): Yellow
One SPDT relay (NC operation)
Rated load
Maximum contact voltage:
Maximum contact current:
Maximum switching capacity: 1,500 VA
Minimum load:
Mechanical life:
Electrical life:
25% to 85% (with no condensation)
25% to 85% (with no condensation)
2,000 m max.
0.49 N·m
Recommended wire
Note: 1. Ferrules with insulating sleeves must be used with twisted wires.
Recommended ferrules
Munsell 5Y8/1
ABS resin (self-extinguishing resin) UL94-V0
Approx. 110 g
Mounted to DIN Track or via M4 screws (tightening torque: 1.2 N·m)
22.5 (W)
20 to 60°C (with no condensation or icing)
40 to 70°C (with no condensation or icing)
Resistive load
6 A at 250 VAC (cos = 1)
6 A at 30 VDC (L/R = 0 ms)
Inductive load
1 A at 250 VAC (cos = 0.4)
1 A at 30 VDC (L/R = 7 ms)
Solid wire:
Twisted wires: AWG16, AWG18
Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact
Al 1-8RD (for AWG18) manufactured by Phoenix Contact
Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact
2. Two wires can be twisted together.
90 (H)
K8AB-PH
2.5 mm
100 (D) mm
2
250 VAC
6 A AC
10 mA at 5 VDC
10,000,000 operations
Make: 50,000 times, Break: 30,000 times
Cat. No. N145-E1-02