A16-24DSY Omron, A16-24DSY Datasheet - Page 27

24V YELLOW LED

A16-24DSY

Manufacturer Part Number
A16-24DSY
Description
24V YELLOW LED
Manufacturer
Omron
Type
Pushbutton Switchr
Datasheets

Specifications of A16-24DSY

Color
Yellow
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Z1311 - SWITCH PB RND MOM DPDT ILLUM YLWZ1310 - SWITCH PB RND MOM DPDT ILLUM WHTZ1309 - SWITCH PB RND MOM DPDT ILLUM REDZ1308 - SWITCH PB RND MOM DPDT ILLUM GRNZ1307 - SWITCH PB RECT MOM DPDT ILLUMZ1306 - SWITCH PB RECT MOM DPDT ILLUMZ1305 - SWITCH PB RECT MOM DPDT ILLUMZ1304 - SWITCH PB RECT MOM DPDT ILLUMZ1303 - SWITCH PB SQ MOM DPDT ILLUM YLLWZ1302 - SWITCH PB SQ MOM DPDT ILLUM WHTZ1301 - SWITCH PB SQ MOM DPDT ILLUM REDZ1300 - SWITCH PB SQ MOM DPDT ILLUM GRN
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A16-24DY
A16-24DY
A1624DSY
Z1585
Removing the Lamp
(1) Removing from the Pushbutton End
(2) Removing from the Switch End
Mounting the A16Z Dust Cover
Mounting the A16Z Switch Guard
Set
A16ZJ-5060
The Lamp can be removed by hand once the Switch is removed
using the A16Z-5080 Extractor.
Lamp
Grip the Lamp with the
A16Z-5080 Extractor
and pull to remove.
Cover B
(transparent)
Pushbutton Unit
Cover A
(black)
Switch Unit
Panel
Lock ring
Mounting nut
Switch Guard
Panel
Pushbutton Unit
Lock ring
Mounting nut
Switch Unit
Installing the Lamp
• When mounting the Lamp, make sure it is facing the direction
• The Lamp can be mounted from the Pushbutton end by using the
shown in the following diagram. Insert the Lamp while matching the
protruding part of the Lamp and the small guides on the outer
surface of the Case.
A16Z-5080 Extractor.
The lamp can be mounted by following the opposite procedure for
removing the Lamp.
1. Separate the Dust Cover into 2 parts: cover A and cover B.
2. Insert the Case (Pushbutton Unit) into cover A.
3. Mount these parts together onto the panel.
4. From the back of the panel, mount the lock ring and secure with the
5. Insert cover B into cover A. Ensure that the entire perimeter of cover B
6. Mount the Switch Unit to the Case.
Note: Recommended panel thickness: 0.5 to 2 mm.
1. Insert the Case (Pushbutton Unit) into the Switch Guard.
2. Mount these parts together onto the panel.
3. From the back of the panel, mount the lock ring and secure with the
4. Attach the Switch Unit to the Case.
Note: Recommended panel thickness: 0.5 to 2 mm.
mounting nut.
is securely attached to cover A by pressing in different directions.
mounting nut.
Protruding part
A16
27

Related parts for A16-24DSY