E-stop,lighted,2NC,30diameter

A165E-LS-24D-02

Manufacturer Part Number
A165E-LS-24D-02
Description
E-stop,lighted,2NC,30diameter
Manufacturer
Omron
Series
A16r
Type
Emergency Stop, Illuminatedr
Datasheets

Specifications of A165E-LS-24D-02

Circuit
DPST-NC
Switch Function
On-Off
Contact Rating @ Voltage
5A @ 125VAC
Actuator Type
Round Button
Illumination Type, Color
LED, Red
Illumination Voltage (nominal)
24 VDC
Mounting Type
Panel Mount
Termination Style
Solder, Quick Connect - .110" (2.8mm)
Illumination
Red
Control Type
Emergency Stop
Contact Form
DPST - NC
Contact Rating
5 Amps at 125 VoltsAC
Illuminated
Y
Lens Color
Red
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A165ELS24D02
Z1426
Installation
Mounting to the Panel (Models with Separate Construction)
After installing the Operation Unit, snap in the Switch from the back of the panel.
• Attach rubber packing or the
• Adjust the slits on the hole of
• Rubber packing is not necessary
• Tighten the nut to the torque of
• The Operation Unit should be
• Align the lock ring to the groove of
• Snap on the Switch to the Operation Unit.
• Make sure that the Switch has the correct orientation when snapping it onto the
• Align the white dot on the Operation Unit with the guide groove on the side of
• When mounting the Lamp, make sure it is facing the direction shown in the
Yellow Plate onto the Operation
Unit from its terminal side. Insert
the Operation Unit into the panel
from the front. Install the lock ring
and mounting nut from the
terminal side and tighten.
rubber packing and Yellow Plate
to the protruding part of the Unit.
when the Yellow Plate is used.
0.29 to 0.49 N·m.
installed with its
protruding part adjusted to the slit
of the panel hole.
the Operation Unit so that the
edge is drawn to the panel side.
Operation Unit.
the Switch marked with an “L” as shown below, and push the Switch into the
Operation Unit until it clicks into place. Confirm that the Switch is securely in
place before using.
following diagram. Insert the Lamp while matching the protruding part of the
Lamp and the small guides on the outer surface of the switch.
Protruding part
(4) Installing the LED Lamp
(2) Mounting the Switch
White dot
Wide guide
Lock hole
Guide groove
Narrow guide
Cutout
Lock
(1) Installing the Operation Unit
L marking
Mounting nut (included
with the product)
Rubber packing
(included with the
product) or Yellow
Plate (sold separately)
Lock ring (included
with the product)
• Insert the prongs of the A16Z-5080 Extractor between the Switch and the
Panel
Operation Unit, grip the Switch, and pull to remove.
(3) Removing the Switch
Extractor (A16Z-5080)
Rubber packing (included with the product)
or Yellow Plate (sold separately)
Panel
Edge
Lock ring (included
with the product)
Mounting nut
A165E
8

Related parts for A165E-LS-24D-02