A22EL-M-12A-01 Omron, A22EL-M-12A-01 Datasheet - Page 8

no-image

A22EL-M-12A-01

Manufacturer Part Number
A22EL-M-12A-01
Description
Lighted,pushlock,turnreset,1NC
Manufacturer
Omron
Series
A22r
Type
Emergency Stop, Illuminatedr
Datasheet

Specifications of A22EL-M-12A-01

Circuit
SPST-NC
Switch Function
On-Off
Contact Rating @ Voltage
10A @ 110VAC
Actuator Type
Mushroom Button
Illumination Type, Color
LED, Red
Illumination Voltage (nominal)
12 VAC/DC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A22ELM12A01
*1. These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any other applications (e.g.
*2. The A22-B101Y cannot be used in combination with the A22Z-EG@.
Specifications
Certified Standard Ratings
Ratings
Contacts (Standard Load)
10
E-stop Shroud for EMO,
Yellow
E-stop Shroud for EMO,
Yellow
E-stop Shroud for EMS,
White
E-stop Shroud for EMS,
White
E-stop Shroud, Yellow
• UL, cUL (File No.E41515)
• TÜV (EN60947-5-1) (Low Voltage Directive)
• CCC (GB14048.5)
current
Rated
6A at 220 VAC, 10 A at 110 VAC
3 A at 220 VAC
3 A at 240 VAC, 1.5 A at 24 VDC
carry
emergency stop switches for machines or devices such as Machine tools, Printing presses, Industrial machinery, etc).
(A)
Item
24 VAC
110 VAC 5
220 VAC 3
380 VAC 2
440 VAC 1
24 VDC
110 VDC
220 VDC
380 VDC
voltage
Rated
(V)
10
---
(inductive
AC15
load)
Appearance
10
10
6
3
2
---
(resistive
Rated current (A)
AC12
load)
---
1.5
0.5
0.2
0.1
(inductive
DC13
load)
---
Legend plate for
EMERGENCY OFF is not
included.
---
Legend plate for
EMERGENCY STOP is not
included.
---
---
10
2
0.6
0.2
(resistive
DC12
load)
Classification
Certified Standards
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 and bears the
*2. Some models have been certified.
Note: 1. Rated current values are determined according to the
LED Indicators without Voltage Reduction Unit
UL *1
TÜV SÜD
CQC (CCC)
KOSHA *2
6 VAC/VDC
12 VAC/VDC
24 VAC/VDC
Certification body
Certification has been obtained for the Switch Unit and the Lamp Socket.
Rated voltage
2. Minimum applicable load: 10 mA at 5 VDC
A22Z-EG1
A22Z-EG10
A22Z-EG1-W
A22Z-EG10-W
A22Z-EG2
testing conditions. The above ratings were obtained by
conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
Model
UL508, C22.2 No.14
EN60947-5-1,
EN60947-5-5
(certified direct
opening mechanism)
GB14048.5
EN60947-5-1
8 mA
Rated current
Provides SEMI-S2/SEMATECH
Application Guide for SEMI-S2
compatibility. The SEMI-S2-compatible
Shroud and legend plate for
EMERGENCY OFF come as a set. Use
with an A22E Emergency Stop Switch.
(for emergency shutoff) *1 *2
Provides SEMI-S2/SEMATECH
APPLICATION GUIDE FOR SEMI S2
compatibility. Use with an A22E with
EMO indication. (for emergency off) *2
Provides SEMI-S2/SEMATECH
Application Guide for SEMI-S2
compatibility. The SEMI-S2-compatible
Shroud and legend plate for
EMERGENCY STOP come as a set.
Use with an A22E Emergency Stop
Switch. (for emergency stop) *1*2
Provides SEMI-S2/SEMATECH
APPLICATION GUIDE FOR SEMI S2
compatibility. Use with an A22E with EMS
indication. (for emergency stop) *2
SEMI-S2/SEMATECH Application
Guide for SEMI S2-compatible Shroud.
(for emergency shutoff) *1*2
Use together with an A22E Emergency
Stop Switch.
Standards
Remarks
6 VAC/VDC±5%
12 VAC/VDC±5%
24 VAC/VDC±5%
E41515
Inquire
2003010303070635
2004-220, 2007-27
2009-189
(A22E-@-@-EMS/EMO)
Operating voltage
File No.
A22E
mark.
8

Related parts for A22EL-M-12A-01