A22Z-B101Y Omron, A22Z-B101Y Datasheet - Page 24

PB ENCL. 1 HOLE YELLOW

A22Z-B101Y

Manufacturer Part Number
A22Z-B101Y
Description
PB ENCL. 1 HOLE YELLOW
Manufacturer
Omron
Type
Control Boxr
Series
A22r
Datasheets

Specifications of A22Z-B101Y

Accessory Type
Control Box Enclosure
Color
Yellow
Illumination
Not Illuminated
Height
69.5 mm
Length
75 mm
Mounting Style
Panel
Termination Style
Wire
Width
68 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
A22 Series
For Use With
A22EL-M - SWITCH UNIT PB EMRGNCY STOP 40MMA22E-SK - SWITCH UNIT PB EMERGNCY STOP KEYA22E-S - SWITCH UNIT PB EMRGNCY STOP 30MMA22E-MP - SWITCH UNIT PB EMRGNCY STOP 40MMA22E-MK - SWITCH UNIT PB EMERGNCY STOP KEYA22E-M - SWITCH UNIT PB EMRGNCY STOP 40MMA22E-L - SWITCH UNIT PB EMRGNCY STOP 60MMA22EL-M-T2-11 - SWTCH PB EMRGNCY STOP ILLUM SPSTA22EL-M-T2-02 - SWTCH PB EMRGNCY STOP ILLUM DPSTA22EL-M-T2-01 - SWTCH PB EMRGNCY STOP ILLUM SPSTA22EL-M-T1-11 - SWTCH PB EMRGNCY STOP ILLUM SPSTA22EL-M-T1-02 - SWTCH PB EMRGNCY STOP ILLUM DPSTA22EL-M-24A-11 - SWTCH PB EMRGNCY STOP ILLUM SPSTA22EL-M-24A-02 - SWTCH PB EMRGNCY STOP ILLUM DPSTA22EL-M-12A-11 - SWTCH PB EMRGNCY STOP ILLUM SPSTA22EL-M-12A-02 - SWTCH PB EMRGNCY STOP ILLUM DPSTA22EL-M-12A-01 - SWTCH PB EMRGNCY STOP ILLUM SPSTA22E-SK-11 - SWITCH PB EMRGNCY STOP SPST-NO/CA22E-SK-02 - SWITCH PB EMERGENCY STOP DPST-NCZ3128 - SWITCH PB EMRGNCY STOP SPST-NO/CA22E-S-02 - SWITCH PB EMERGENCY STOP DPST-NCA22E-S-01S - SWITCH PB EMERGENCY STOP SPST-NCA22E-MP-02 - SWITCH PB EMERGENCY STOP DPST-NCA22E-MK-02 - SWITCH PB EMERGENCY STOP DPST-NCZ3129 - SWITCH PB EMRGNCY STOP SPST-NO/CA22E-M-02 - SWITCH PB EMERGENCY STOP DPST-NCA22E-LP-11 - SWITCH PB EMRGNCY STOP SPST-NO/CA22E-LP-02 - SWITCH PB EMERGENCY STOP DPST-NCA22E-L-11 - SWITCH PB EMRGNCY STOP SPST-NO/CA22E-L-02 - SWITCH PB EMERGENCY STOP DPST-NCZ1511 - SWTCH PB EMRGNCY SPST-NC ILLZ1510 - SWTCH PB EMRGNCY SPST-NC ILLZ1509 - SWITCH PB EMRGNCY STP SPST-NCZ1508 - SWITCH PB EMRGNCY STP SPST-NCZ1507 - SWITCH PB EMRGNCY SPST-NO/NCZ1506 - SWITCH PB EMRGNCY STP SPST-NCZ1560 - SWITCH PB EMRGNCY SPST-NO/NCZ1505 - SWITCH PB EMRGNCY STP SPST-NCZ1504 - SWITCH PB EMRGNCY STP SPST-NCZ1503 - SWITCH PB EMRGNCY STP SPST-NCZ1502 - SWITCH PB EMRGNCY STP SPST-NC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A22Z-B101Y
A22ZB101Y
Z1648
Application
Mounting to the Panel
Panel Hole Dimensions
• Panel hole dimensions are given below.
• Recommended panel thickness: 1 to 5 mm.
• For 25-dia. holes, always use 25-dia. Rings. (Since the cutout
• If outer surface treatment such as coating is performed for the
dimensions are large, IP65 cannot be guaranteed unless 25-dia.
Rings are used.)
panel, the panel dimensions after outer surface treatment must
meet the specified panel dimensions.
Not Using a Lock Ring
22.3
+0.4
0
22 dia.
Using a Lock Ring
3.2
+0.2
0
22.3
+0.4
0
25
+0.5
0
25 dia.
Matrix Installation
1. The following panel hole dimensions
2. The following panel hole dimensions
For 1. above:
For 2. above:
Note: 1. The above dimensions are the minimum dimensions for when the wires
Mounting the Operation Unit on the Panel
Pitches A and B between the centers of the mounting holes are as follows:
Type of crimp terminal
Bare crimp terminals
Crimp terminals with
insulating sheath
• Insert the Operation Unit (Pushbutton, etc.) from the front surface of the
• When using a Legend Plate Frame, put one rubber washer each
• Align the Lock Ring with the groove in the casing, then insert the
panel, insert the Lock Ring and the mounting nut from the terminal side,
then tighten the nut. Before tightening, check that the rubber washer is
present between the Pushbutton Unit and the panel.
between the Legend Plate Frame and the panel and between the
Operation Unit and the Legend Plate Frame. (One rubber washer
will be provided when one Legend Plate Frame is ordered.)
Lock Ring so that its edge is located on the panel side.
apply when Switch Unit and the
Standard-size Legend Plate Frame and
Lock Ring are mounted, and lead wires
are connected directly to the Switch
Block.
apply when the Large-size Legend Plate Frame is mounted, and
when crimp terminals are connected to the Switch Block terminals.
2. With pushbuttons of external dimensions greater than 30 mm, set the
described under Applicable Wire Size on page 23 are used. If a
different wires are used, the wiring dimensions may be different so
determine an appropriate pitch before setup.
pitch according to the dimensions. (When using matrix installation for
the A22-M@, mount with a pitch of 40 mm instead of 30 mm in the
diagram above.)
A22-10, A22-10S
A22-01, A22-01S
A22-20, A22-20S, A22-02
A22-02S, A22-11, A22-11S
Switch Blocks
A22-10, A22-10S
A22-01, A22-01S
A22-20, A22-20S, A22-02
A22-02S, A22-11, A22-11S
A22-10, A22-10S
A22-01, A22-01S
A22-20, A22-20S, A22-02
A22-02S, A22-11, A22-11S
Switch Blocks
30
30
45 mm min.
55 mm min.
51 mm min.
61 mm min.
60 mm min.
70 mm min.
A22
A
B
B
A
24