CJ1W-CLK23 Omron, CJ1W-CLK23 Datasheet - Page 8

no-image

CJ1W-CLK23

Manufacturer Part Number
CJ1W-CLK23
Description
Controller Link Mod Twist Pair
Manufacturer
Omron
Datasheet

Specifications of CJ1W-CLK23

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Differences in Specifications of New and Old Models
The following table shows the main differences in specifications between the new and old models.
Number of data link send words
(data link areas that are created for
a single node in a single PLC)
Number of send words per node
(total of area 1 and area 2)
Data Link Area
Max. Units mountable per PLC
Automatic data link setting
Changing data link allocations
during active data links
Maximum connectable nodes
Mixed use
Compatible support software
Note:
1. For wired models, the maximum number of nodes is 32 if Repeater Units are not used.
2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models.
The following table shows the main differences in specifications between the new and old models of Controller Link Support Boards.
Number of data link send/receive
words
(data link areas for send-
ing/receiving that are created for a
single node in a single computer)
Send words per node
Changing data link allocations
during active data links
Maximum connectable nodes
Mixed use
Compatible FinsGateway and
version of supplied CD
Compatible support software
Note:
1. For wired models, the maximum number of nodes is 32 if repeater units are not used.
2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models.
3. FinsGateway Version 2003 is compatible with Windows XP and Windows 2000. For Windows NT4.0 (Service Pack 3 or higher), Windows ME, or Windows
(See note 3.)
The data link send/receive words can be separately set to their maximums when new and old models are mixed.
The data link send/receive words can be separately set to their maximums when new and old models are mixed..
98SE, use FinsGateway Version3. (With FinsGateway Version 3, only functions supported by the 3G8F7-CLK21 can be used.)
Functions
Functions
20,000 max.
4,000 words max.
(user-set links only)
Allocation setting can be performed for same areas in areas 1 and 2.
8 Units
Choose from equality layout or 1:N allocations (common type, 1:1, chain type)
Supported (Data link tables can be changed during active data links.)
62 nodes (See note 1.)
Yes (See note 2.)
CX-Integrator for CX-One V2.1or
higher, or CX-Net for
CX-Programmer Ver. 7.2 or
higher
62,000 max.
4,000 words max. (user-set links only)
Supported. (Data link tables can be changed during active data links.)
62 nodes (See note 1.)
Yes (See note 2.)
FinsGateway Version 2003.21 or higher
(CD Ver. 3.00 or higher)
CX-Integrator for CX-One Ver. 2.1 or
higher , or CX-Net for CX-Programmer Ver.
7.2 or higher
Unit version 2.0
CJ1W-CLK23
3G8F7-CLK23-E
1,000 words max.
CX-Net for CX-Programmer Ver.
5.0 or higher
CJ1W-CLK21-V1
Unit version 1.2
1,000 words max.
FinsGateway Version 2003.00 or higher
(CD Ver. 2.00 or higher)
CX-Net for CX-Programmer Ver. 3.2 or higher CX-Net for Ver. 1.0 or higher
3G8F7-CLK21-EV1
12,000 max.
Allocation setting can be performed for same areas in areas 1 and 2.
4 Units
CX-Net for CX-Programmer Ver.
3.2 or higher
Note: The following models
are discontinued.
CJ1W-CLK21-V1
Pre-Ver. 1.2
32,000 max.
Not supported.
32 nodes
FinsGateway Version 3.00 or higher
(CD Ver. 1.00 or higher)
Note: The following models are
Supported for equality layout
only.
Not supported.
32 nodes
CX-Net for CX-Programmer Ver.
1.0 or higher
3G8F7-CLK21-E
Note: The following models
discontinued.
are discontinued.
CJ1W-CLK21
Pre-Ver. 1.2
8