D4BL-3CRB Omron, D4BL-3CRB Datasheet - Page 4

SAFETY-DOOR LIMIT SWITCH

D4BL-3CRB

Manufacturer Part Number
D4BL-3CRB
Description
SAFETY-DOOR LIMIT SWITCH
Manufacturer
Omron
Type
Safety Limit Switchr
Datasheets

Specifications of D4BL-3CRB

Contact Form
DPDT
Contact Rating
10 Amps
Actuator
Plunger
Operating Force
19.61 N
Termination Style
Wire
Contact Configuration
3PST-2NC / 1NO
Contact Voltage Ac Max
250V
Contact Current Ac Max
10A
Switch Terminals
Screw
Circuitry
3PST-2NC/1NO
Contact Current Max
10A
Mounting Type
Conduit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J CHARACTERISTICS
Note: 1. The values provided in the above table are the initial values.
Solenoid Coil Characteristics
Indicator Characteristics
Degree of protection
Life expectancy (See note 3.)
Operating speed
Operating frequency
Rated frequency
Operating characteristics
Locked resistive pulling force
Insulation resistance
Rated insulation voltage (U
Conventional enclosed thermal
current (I
current)
Dielectric strength (U
Conditional short-circuit current
Operating environmental pollution
level
Electric shock protection class
Counter electromotive voltage at
switching
Contact resistance
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Item
Rated operating voltage
Current consumption
Insulation class
Item
Rated voltage
Current consumption
Indicator color (LED)
2. Although the switch box does not allow the penetration of dust, oil or water, avoid as much as possible the penetration of dust,
3. The life expectancy is for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further conditions,
the
oil, or water into the head’s Operation Key insertion slot.
consult your OMRON sales representative.
) (rated continuous
imp
)
i
)
24-VDC Mechanical lock models
24 VDC
Approx. 300 mA
Class F (130°C or less)
LED
10 to 115 VAC/VDC
Approx. 1 mA
Orange, green
+10%
IP67 (See note 2.)
Mechanical: 1,000,000 operations min.
Electrical: 500,000 operations min.
0.05 to 0.5 m/s
30 operations/min max.
50/60 Hz
Positive opening force: 19.61 N min. (EN60947-5-1)
Positive opening stroke: 20 mm min. (EN60947-5-1)
All stroke: 23 mm min.
700 N min. (GS-ET-19)
100 MΩ min. (at 500 VDC)
300 VAC (EN60947-5-1)
10 A (EN60947-5-1)
Impulse dielectric strength (U
between each terminal and ground, and between each terminal and non-current-carrying metal
part;
2.5 kV between solenoid and ground
100 A (EN60947-5-1)
Pollution degree 3 (EN60947-5-1)
Class I (with grounded terminal)
1,500 V max. (EN60947-5-1)
50 mΩ max. (initial value)
Malfunction: 10 to 55 Hz, 0.35-mm single amplitude with an imposed acceleration of 50 m/s
max. (IEC68-2-6)
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating: --10°C to 55°C (with no icing)
Operating: 95% max.
Approx. 800 g
/
--15%
(100% ED)
2
min. (IEC68-2-27)
2
min. (IEC68-2-27)
110-VAC Mechanical lock
models
110 VAC ±10% (50/60 Hz)
Approx. 98 mA
5
imp
) 4 kV (EN60947-5-1) between terminals of different polarity,
24-VAC Solenoid lock models
24 VDC
Approx. 300 mA
+10%
/
--15%
(100% ED)
D4BL
2

Related parts for D4BL-3CRB