Specifications of D4NS-8CF

Lead Free Status / Rohs Status
 Details
Safety Precautions
Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches”.
Stopper Installation
Do not use a Switch as a stopper. Be sure to install a stopper as
shown in the following illustration to ensure that the base of the
Operation Key does not strike the Head, and adjust the stopper to be
within the setting zone (0.5 to 3 mm) of the base of the Operation Key.
Do not subject the Switch to a shock that exceeds the Switch's shock
resistance of 1,000 m/s
The Switch contacts can be used with either standard loads or
microloads. Once the contacts have been used to switch a load,
however, they cannot be used to switch smaller loads. The contact
surfaces will become rough once they have been used and contact
reliability for smaller loads may be reduced.
Mounting Method
Appropriate Tightening Torque
Electric shock may occasionally occur.
Do not use metal connectors or metal conduits.
• Do not use the Switch submersed in oil or water or in locations
• Always attach the cover after completing wiring and before using
• Do not switch circuits for two or more standard loads (250 VAC,
• Loose screws may result in malfunction. Tighten the screws to the
Terminal screw
Cover mounting screw
Head mounting screw
Operation Key mounting screw
Body mounting screw
Connector and M12 adaptor
Cap screw
• When loosening a screw with an electrical screwdriver or similar
continuously subject to splashes of oil or water. Doing so may
result in oil or water entering the Switch. (The IP67 degree of
protection of the Switch specifies the amount of water penetration
after the Switch is submerged in water for a certain period of time.)
the Switch. Also, do not turn ON the Switch with the cover open.
Doing so may result in electric shock.
3 A). Doing so may adversely affect insulation performance.
specified torques.
tool while pressing down on the screw head, do not continue
turning the screw past the point where the threads disengage.
Doing so may strip the end of the threads.
Correct
Operation key
Precautions for Correct Use
Precautions for Safe Use
Switch
Stopper
2
.
!CAUTION
Incorrect
0.6 to 0.8 N·m
0.5 to 0.7 N·m
0.5 to 0.6 N·m
2.4 to 2.8 N·m
0.5 to 0.7 N·m
1.8 to 2.2 N·m (except 1/2-14NPT)
1.4 to 1.8 N·m (1/2-14NPT)
1.3 to 1.7 N·m
Mounting Holes
Head Direction
Securing the Door
When the door is closed (with the Operation Key inserted), the
Operation Key may exceed the set zone because of, for example, the
door's own weight, machine vibration, or the door cushion rubber.
Secure the door with a stopper so that the Operation Key remains
within the set zone.
2.5
• Use M4 screws and spring washers to mount the Switch and
• As shown below, two studs with a maximum height of 4.8 mm and
• Set the Operation Key so that it is within 1 mm of the center of the
• Observe the specified insertion radius for the Operation Key and
• The rotation of the Switch head may be adjusted to any of the four
• Do not insert or remove the Operation Key with the Switch head
Switch Mounting Holes and Studs
5.35
• 1-Conduit Modules
• 2-Conduit Modules
±0.1
Operation Key, and tighten the screws to a suitable torque. To
ensure safety, use screws that cannot be easily removed or
another means to prevent the Switch and Operation Key from
easily being removed.
a diameter of 4
holes on the bottom of the Switch, and the Switch secured at four
locations to increase the mounting strength.
key hole. If the Operation Key is offset or at an angle, accelerated
wear or breaking may result.
insert it in a direction perpendicular to the key hole.
directions by loosening the head mounting screws at the four
corners of the head. Make sure that no foreign materials enter
through the head.
removed. Doing so may make it impossible to insert the Operation
Key.
47
±0.1
2.5
39
±0.1
±0.1
±0.1
Two, M4
20
22
22
Two, M4
±0.1
±0.1
±0.1
−0.05
−0.15
20
22
40
42
42
±0.1
±0.1
±0.1
±0.1
±0.1
mm can be provided, the studs inserted into the
4
Height: 4.8 max.
-0.15
-0.05
Set zone
(0.5 to 3 mm)
dia.
4
Height: 4.8 max.
-0.15
-0.05
dia.
Operation Key Mounting Holes
• Horizontal/Vertical Mounting
• Horizontal Adjustable
• Horizontal/Vertical Adjustable
Operation Key
(D4DS-K1/-K2)
Mounting (D4DS-K3)
Mounting (D4DS-K5)
41
±0.1
15
40
±0.1
or, 43
±0.1
Two, M4
±0.1
Two, M4
Two, M4
D4NS
10