E8F2-B10B Omron, E8F2-B10B Datasheet - Page 5

no-image

E8F2-B10B

Manufacturer Part Number
E8F2-B10B
Description
MINI-CUBE PRESS, 1MPa, PNP
Manufacturer
Omron
Series
E8F2r
Type
Gager
Datasheet

Specifications of E8F2-B10B

Pressure Type
Gauge
Operating Pressure
1.45 PSI, 1 MPa
Port Size
Female, 1/8" (3.175mm) NPN
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
0°C ~ 55°C
Package / Case
Module
Output Voltage Range
1 to 5V
Pressure Range
0 to 1000KPa
Mounting
Screw
Operating Temp Range
0C to 55C
Operating Temperature Classification
Commercial
Operating Supply Voltage (typ)
15/18V
Operating Supply Voltage (min)
12V
Operating Supply Voltage (max)
24V
Mounting Style
Screw
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
0 C
Operating Supply Voltage
15 V, 18 V
Output Voltage
1 V to 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8F2B10B
Nomenclature
Display Panel
(1) Bar Indicator (Green)
(2) Numeric and Menu Display (Red)
(3) Unit indicator (Green)
(4) OUT1 Indicator (Orange)
(5) OUT2 Indicator (Orange)
Indicates the degree of measured pressure in relation to the set
pressure.
Indicates measurement values and setting menu items.
Indicates the unit used for detection. The unit indicated on the
indicator is the one currently set.
Lit when OUT1 is turned ON.
Lit when OUT2 is turned ON.
(1)
(4)
(5)
(6)
(7)
Operation Keys
(6)
(8)
• Used to select or change the set items, set contents, and set values
• Press either key to check the ON and OFF points in measurement
• Use together with the SET Key for setting the Sensor to a special
• Used for entering the set contents and set values in setting mode.
• Used for setting the Sensor to basic setting mode or pressure
in setting mode.
mode. The values are reset by pressing both keys simultaneously.
setting mode or energy-saving mode.
setting mode.
SET
(8)
SET Key
Up Key, (7)
(2)
(3)
Down Key
E8F2
5

Related parts for E8F2-B10B