F150-M05L Omron, F150-M05L Datasheet - Page 7

no-image

F150-M05L

Manufacturer Part Number
F150-M05L
Description
5.5Panel Mnt. Clr LCD Monitor
Manufacturer
Omron
Datasheets

Specifications of F150-M05L

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Rating/performance
Sensor: Z300-S2T/Z300-S5T/Z300-S10/Z300-S60
Note: 1 . Defined at 1/e
Z300
Distance to
measurement center
Measurement range
Light source
Beam dimensions
(See note 1.)
Linearity
Resolution
Sampling period
(See note 10.)
Temperature charac-
teristic (See note 11.)
Materials
Cable length
Minimum bending
radius
Weight
Accessories
Measurement mode
2 . Error with respect to the theoretical line representing the displacement output for measurement of OMRON standard SUS blocks. The linearity varies with the
NEAR indicator
FAR indicator
Degree of
protection
Ambient operating
illumination
Ambient
temperature
Ambient humidity Operating and storage: 35 % to 85 % (with no condensation)
Vibration
resistance
workpiece is high compared to the workpiece, measurement may be affected.
type of workpiece.
Model
2
(13.5 %) of the density at the light center. Light may, however, be present outside this range and if the reflection factor of the light around the
±5.2 mm
Visible-light
semiconductor laser
(Wavelength: 650 nm,
1 mW max., Class 2)
20 µm
(distance to measurement center)
* Measurement region
±0.05 %F.S.
(See note 2.)
0.4 µm
(See notes 5 and 6.)
540 µs
Lights if the workpiece is close to the measurement center or is on the near side of the measurement center
and inside the measurement region.
Flashes if the workpiece is outside the measurement region or if the density is excessive or insufficient.
Lights if the workpiece is close to the measurement center or is on the far side of the measurement center and
inside the measurement region.
Flashes if the workpiece is outside the measurement region or if the density is excessive or insufficient.
±0.01 %F.S./° C
IEC IP64
Illumination at light-receiving surface: 3,000 lx max., incandescent light
Operating: 0 to +50 ° C, Storage: -15 to +60 ° C (with no icing or condensation)
10 to 150 Hz (double amplitude: 0.35 mm) for 8 min. each in X, Y, and Z directions
Unit: Die-cast aluminum; Cable sheathing: Heat-resistant chlorinated vinyl
Connector: Zinc alloy and brass
2 m
68 mm
Approx. 600 g
(Unit: Approx. 350 g)
3 ferrite cores, laser warning labels (English)
Diffuse reflection Mirror reflection Diffuse reflection Mirror reflection Diffuse reflection Mirror reflection Diffuse reflection only
±1 mm
×
300 µm (200 µm*) TYP.
Z300-S2T
20 mm
(with beam cover
attached: 16 mm)
±0.05 %F.S.
(See note 3.)
±50 mm
±5 mm
Visible-light semiconductor laser
(Wavelength: 670 nm, 1 mW max., Class 2)
30 µm
(distance to measurement
center)
±0.1 %F.S. (See note 4.)
0.4 µm
(See notes 7 and 9.)
IEC IP67
Approx. 800 g (Unit: Approx. 600 g)
×
Z300-S5T
400 µm TYP.
±44 mm
±4 mm
±100 mm
±20 mm
60 µm
(distance to measurement
center)
1 µm
(See notes 7 and 8.)
×
Z300-S10
1000 µm TYP.
±94 mm
±16 mm
±600 mm
±350 mm
(F.S.700 mm)
Visible-light
semiconductor laser
(Wavelength: 658 nm,
15 mW max., Class 3B)
0.3 mm
mm (at 500 mm)
* Measurement region
±0.07 %F.S.
(250 to 750 mm)
±0.1 %F.S.
(750 to 950 mm)
(See note 4.)
8 µm (at 350 mm)
40 µm (at 600 mm)
(See notes 7 and 8.)
IEC IP66
50 cm
Approx. 800 g
(Unit: Approx. 700 g)
Z300-S60
×
16 (10.3*)
B-37

Related parts for F150-M05L