G3J-T217BL-C DC12-24 Omron, G3J-T217BL-C DC12-24 Datasheet - Page 3

no-image

G3J-T217BL-C DC12-24

Manufacturer Part Number
G3J-T217BL-C DC12-24
Description
SSR CONTROLLER
Manufacturer
Omron
Series
G3J-Tr

Specifications of G3J-T217BL-C DC12-24

Circuit
SPST-NO (1 Form A)
Output Type
AC
Load Current
17.4A
Voltage - Input
10.2 ~ 26.4VDC
Voltage - Load
180 ~ 264 V
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3J-T217BL-CDC12-24
G3JT217BLCDC1224
G3JT217BLCDC1224NC
■ Characteristics (for Both AC and DC Models)
Note: 1. Provided that the starting torque is 600% In when the motor is started at full voltage.
Connections
■ Connection Examples
AC Model G3J-T@BL-C
Note: Harmonized protection for motor overload is ensured by using a thermal relay. Be sure, however, to install protective devices on the power
Item
Ramp-up time
Ramp-down time
Starting torque (See note 1.)
Monitor output operate time (See note 2.) After control signal input: AC model: 300 ms max. (TYP 50 ms), DC model: 50 ms max.
Monitor output release time (See note 2.) After ramp-down time completion (after main circuit current turns OFF): 60 ms max.
Output ON voltage drop (main circuit)
Output ON voltage drop (monitor output) AC model: 3.5 VAC max., DC model: 2.0 VDC max.
Leakage current (main circuit)
Leakage current (monitor output)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Storage temperature
Ambient operating temperature
Ambient operating humidity
Weight
Three-phase, 200 to 220 V
L1/R
T1/U
2. The monitor output will be ON while load current is flowing to the main circuit.
supply side, such as fuses and non-fuse breakers, as protection against accidents due to short-circuiting.
G3J
L2/S
T2/V
M
Motor
L3/T
T3/W
Thermal Relay
1
2
3
4
5
6
7
8
Ry
100 to
240 VAC
Model
100 to
240 VAC
Set within a range of approx. 1 to 25 s.
Set within a range of approx. 1 to 25 s.
Set within a range of 200% to 450% In.
1.6 V (RMS) max.
10 mA max. (at 200 VAC)
AC model: 1.5 mA max. (at 200 VAC), DC model: 0.15 mA max. (at 24 VDC)
100 MΩ min. (at 500 VDC)
2,500 VAC, 60 Hz for 1 min
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
294 m/s
−30 to 70°C (with no icing or condensation)
−20 to 60°C (with no icing or condensation)
45 to 85 %
Approx. 890 g
DC Model G3J-T@BL-C
(NPN transistor input)
2
G3J-T217BL-C
Three-phase, 200 to 220 V
L1/R
T1/U
G3J
L2/S
T2/V
M
Motor
L3/T
T3/W
1
2
3
4
5
6
7
8
Thermal Relay
Ry
Approx. 760 g
NPN Tr
12 to
24 VDC
G3J-T211BL-C
12 to
24 VDC
(PNP transistor input)
Three-phase, 200 to 220 V
L1/R
T1/U
G3J
Approx. 760 g
L2/S
T2/V
M
Motor
L3/T
T3/W
G3J-T205BL-C
1
2
3
4
5
6
7
8
Thermal Relay
G3J-T-C
Ry
PNP Tr
12 to
24 VDC
12 to
24 VDC
3

Related parts for G3J-T217BL-C DC12-24