... A at 400 to 600 VAC VDC 100 to 240 VAC Low-cost Models Model Applicable maximum load current Y92B-A100 20 A Y92B-A150N 40 A Y92B-A250 40 A Solid State Relays (600 VAC Models) Model G3NA-610B DC5-24 G3NA-610B AC100-240 G3NA-625B DC5-24 G3NA-625B AC100-240 G3NA-650B DC5-24 G3NA-650B AC100-240 G3NA-6 467 ...
Page 2
... VAC max. Applicable load Load voltage range Load current (See note 1.) With heat sink (See note 2.) 0 (at 40°C) 0 (at 40°C) 0 (at 40°C) G3NA-625B-UTU 2 G3NA-6 Voltage level Must release voltage 1 VDC min. 20 VAC min. Inrush current Without heat sink 0 (at 40°C) 150 A (60 Hz, 1 cycle) 0 (at 40° ...
Page 3
... Y92B-N100 Y92B-N150 Y92B-P250N Y92B-A100 Y92B-A150N Y92B-A250 Note: When using a commercially available heat sink, use one with a thermal resistance equal to or less that the OMRON Heat Sink. G3NA-650B 30 25 With standard heat sink (Y92B-N150or Y92B-A150N) 20 With standard heat sink (Y92B-N100 or Y92B-A100) or aluminum plate measuring 15 200 mm x 200 ...
Page 4
... Two screws 58 max. 47.5 44 12±0.4 ■ Optional Accessories (Order Separately) One-touch Mounting Plate The One-touch Mounting Plate is used to mount the G3NA to a DIN Track. R99-12 FOR G3NA (for the G3NA and G3NE) Two, M4 mounting holes for the G3NA 30 Two, M4 mounting ...
Page 5
... Y92B-N150 Heat Sink (for max load current) Type G3NA-625B is recommended for max and G3NA-650B for max with this heat sink. For upright standing to the ground, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions ...
Page 6
... Y92B-P250N (for max load current) Type G3NA-650B is recommended for max with this heat sink. For upright standing to the ground, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions ...
Page 7
... Y92B-A250 Heat Sink (for max load current) Three, M4 holes 47.6 47.6 R2.2 50±0.1 50±0.1 56±0.5 56±0.5 150 max. 250 max. Weight: approx. 510 g Solid State Relays (600 VAC Models) 102 max. 80.5 max. 1.5 9.6 2 1.5 30 45.5 max. G3NA-6 473 ...
Page 8
... Do not use the G3NA if the heat sink fins are bent, e.g., as the result of dropping the G3NA. Heat dissipation characteristics will be reduced, possibly causing G3NA failure. ...
Page 9
... Operating and Storage Locations Do not use or store the G3NA in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • Do not use or store in locations subject to direct sunlight. • Do not use in locations subject to ambient temperatures outside the range −30 to 80°C. ...
Page 10
... Connect the varistor to both sides of the G3NA output terminals. • Do not use an input line that is longer than 3 m. Loss Time The loss time will increase when the G3NA is used at a low applied voltage or current. Be sure that this does not cause any problems. Thickness: 2.3 mm ...
Page 11
... G3NA in locations or by means that will subject it to vibration from other devices, such as motors. 4. Solvents Do not allow the G3NA or the resin portion of the Fan’s thermostat to come in contact with solvents, such as thinners or gasoline. Doing so will dissolve the markings on the G3NA. 5. Oil Do not allow the G3NA terminal cover to come in contact with oil ...
Page 12
... MEMO 478 Solid State Relays (600 VAC Models) G3NA-6 ...
Page 13
... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Solid State Relays (600 VAC Models) G3NA-6 ...
Page 14
... European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Specifications subject to change without notice G3NA-6 Printed in USA ...