Specifications of G3NE-220T-DC12

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
20A
Voltage - Input
9.6 ~ 14.4VDC
Voltage - Load
75 ~ 264 V
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .110"/.250"
Package / Case
Hockey Puck
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NE220TDC12
G3NE220TDC12NC
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Input
*G3NH converts the input current into a constant current.
Output
Note: The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data for
■ Characteristics
5 to 24 VDC
100 to 240 VAC
G3NH-2075B
G3NH-4075B
G3NH-2150B
G3NH-4150B
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Rated voltage
details.
Model
Item
75 to 264 VAC
100 to 240 VAC
180 to 440 VAC
100 to 240 VAC
180 to 440 VAC
4 to 30 VDC
Operating voltage
Rated load voltage
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1.6 V (RMS) max.
30 mA max.
(at 200 VAC)
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude
Destruction: 500 m/s
Operating: –30°C to 80°C (with no icing or condensation)
Storage:
Operating: 45% to 85%
Approx. 1.8 kg
G3NH-2075B
–30°C to 100°C (with no icing or condensation)
2
5 mA max.*
41 kΩ±20%
(Input current)
Impedance
60 mA max.
(at 400 VAC)
75 to 264 VAC
150 to 484 VAC
75 to 264 VAC
150 to 484 VAC
G3NH-4075B
Load voltage range
Applicable load
4 VDC max.
75 VAC max.
Must operate voltage
30 mA max.
(at 200 VAC)
Approx. 3.0 kg
G3NH-2150B
1 to 75 A
1 to 150 A
Load current
Voltage level
(See note.)
1 VDC min.
20 VAC min.
60 mA max.
(at 400 VAC)
Must release voltage
800 A
(60 Hz, 1 cycle)
1,800 A
(60 Hz, 1 cycle)
G3NH-4150B
Inrush current
G3NH
2