G6B-4BND-DC24 Omron, G6B-4BND-DC24 Datasheet - Page 4

RELAY TERMINAL BLOCK -STD.

G6B-4BND-DC24

Manufacturer Part Number
G6B-4BND-DC24
Description
RELAY TERMINAL BLOCK -STD.
Manufacturer
Omron
Series
G6B-4r
Datasheets

Specifications of G6B-4BND-DC24

Relay Type
General Purpose
Contact Form
4PST (4 Form A)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
10.7mA
Coil Voltage
24VDC
Turn On Voltage (max)
19.2 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
4PST (4 Form A)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
19.2 VDC
Control Off Voltage (min)
2.4 VDC
Contact Rating
5 A
Contact Termination
Through Hole
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6B-4BND-DC24
G6B4BNDDC24
Z2983

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6B-4BND-DC24V
Manufacturer:
OMRON
Quantity:
5 400
■ Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928)
Engineering Data
152
G6B-1114P-US
G6B-1114C-US
G6BU-1114P-US
G6BU-1114C-US
G6BK-1114C-US
G6BK-1114C-US
G6B-1174P-US
G6B-1174C-US
G6B-2114P-US
G6B-2114C-US
G6B-2214P-US
G6B-2214C-US
G6B-2014P-US
G6B-2014C-US
G6B-1114P-US
Maximum Switching Capacity
G6B-2114P-US, G6B-2214P-US, G6B-2014P-US
Maximum Switching Capacity
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC inductive load
(cosφ = 0.4)
DC resistive load
Switching voltage (V)
AC inductive load
(cosφ = 0.4)
Switching voltage (V)
Power PCB Relay
Model
AC resistive load
AC resistive
load
G6B
SPST-NO
SPST-NO + SPST-NC
DPST-NO
DPST-NC
Electrical Service Life
Electrical Service Life
Contact form
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7 ms)
G6B-1114P(C)-US
250 VAC/30 VDC
inductive load
(cosφ = 0.4, L/R = 7 ms)
Switching current (A)
G6B-1114P(C)-US
250 VAC/30 VDC resistive load
250 VAC resistive load
30 VDC resistive load
Switching current (A)
G6B-1174P(C)-US
250 VAC/30 VDC
resistive load
3 to 24 VDC
Coil rating
Note: The maximum coil voltage refers
Ambient Temperature vs.
Maximum Coil Voltage
to the maxi-mum value in a
varying range of operating power
voltage, not a continuous voltage.
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
5 A at 250 VAC (General Use) 80°C
5 A at 30 VDC (Resistive) 80°C
8 A at 250 VAC (General Use) 80°C
8 A at 30 VDC (Resistive) 80°C
5 A at 250 VAC (general use) 40°C
5 A at 30 VDC (resistive load) 40°C
Ambient temperature (°C)
G6B-1174P-US
G6B-1114P-US
Contact rating

Related parts for G6B-4BND-DC24