G6E-134P-ST-US-DC5 Omron, G6E-134P-ST-US-DC5 Datasheet - Page 5

LOW SIGNAL RELAY

G6E-134P-ST-US-DC5

Manufacturer Part Number
G6E-134P-ST-US-DC5
Description
LOW SIGNAL RELAY
Manufacturer
Omron
Series
G6Er

Specifications of G6E-134P-ST-US-DC5

Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Standard
Coil Current
40mA
Coil Voltage
5VDC
Control On Voltage (max)
3.5 VDC
Control Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form C
Power Consumption
200 mW
Maximum Switching Current
3 A
Contact Rating
0.40 A at 125 VAC, 2 A at 30 VDC
Current, Rating
0.4⁄2 AAC⁄ADC
Dielectric Rating
1500 VAC @ 50⁄60 Hz (1 Minute)
Dimensions
0.33 in. H x 0.63 in. L x 0.39 in. W
Function
Sensitive
Material, Contact
Ag with Au Clad
Number Of Pins
5
Power, Rating
50⁄60 VA⁄W
Standards
UL, CSA, RoHS
Termination
Solder
Voltage, Control
5 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6E134PSTUSDC5
Z830

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6E-134P-ST-US-DC5V
Manufacturer:
OMRON
Quantity:
12 000
G6EK-134P-ST-US, G6EK-134PL-ST-US
Note: 1.
■ Approvals
UL (File No. E41515)/CSA (File No. LR31928)
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics
Hints on Correct Use
Avoid ultrasonic cleaning at 28 kHz, 13 mW/cm
than 30 seconds.
Single-winding type (G6EU)
Example of low-power consumption driver circuit
1. This is an example of a driver circuit that allows Model G6E to
2. The relay is set by an abrupt current charged to capacity C. This
3. The relay is reset by the discharge current of C flowing in the relay
Note: 1. Give adequate consideration to the circuit constant when
G6E-134P-ST-US
G6E-134PL-ST-US
G6EU-134P-ST-US
G6EK-134P-ST-US
G6EK-134PL-ST-US
function as a normal relay with a normal switching pulse input.
current flows in the relay via diode D
via transistor TR and C.
2. Pay attention to the polarity of the coil.
2. In the interest of product improvement, specifications are subject to change.
3. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings).
2. OMRON owns the patent on this circuit. Consult OMRON
individually defined in this catalog.
actually using this circuit, confirming the set and reset status
of the relay.
when using this circuit.
Type
and
indicate mounting orientation marks.
SPDT
1
and C and out via diode D
Contact form
3
for a period of more
Terminal arrangement/
Internal connections
(Bottom view)
1.5 to 48 VDC
2
.
Coil ratings
Low Signal Relay
0.2 A, 250 VAC (General purpose)
0.6 A, 125 VAC (General purpose)
2 A, 30 VDC (Resistive)
0.6 A, 125 VDC (Resistive)
Mounting holes
(Bottom view, tolerance: ±10 (0.004)
Contact ratings
G6E
5