H5CX-AS-N AC100-240 Omron, H5CX-AS-N AC100-240 Datasheet - Page 50

Scrw Term,Trans OUT,Multi-Fnct

H5CX-AS-N AC100-240

Manufacturer Part Number
H5CX-AS-N AC100-240
Description
Scrw Term,Trans OUT,Multi-Fnct
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-AS-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Transistor
Voltage - Supply
100 ~ 240VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.001 s to 9999 Hrs
Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Display Type
4 Digit LCD Backlight
Product
Digital Timer
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Circuit
-
Contact Rating @ Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H5CXASNAC100240
Z3002
Safety Precautions (H5CX-B)
■ Precautions for Safe Use
Changing the Set Value
When changing the set value during a timing operation, the output
will turn ON if the set value is changed as follows because of the use
of a constant read-in system:
Forecast Value Setting
When the present value ≥ the set value, OUT2 (control output) turns
ON. When the present value ≥ the forecast value (forecast value =
set value − forecast set value) OUT1 (forecast output) turns ON.
Absolute Value Setting
When the present value ≥ set value 2, OUT2 (control output 2) turns
ON. When the present value ≥ set value 1, OUT1 (control output 1)
turns ON.
■ Precautions for Correct Use
Operation with a Set Value of 0
When the set value is 0, the output turns ON the moment the signal
is input. The reset operation turns OFF the output.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
H5CX-B
50