MM2B AC100/(110) Omron, MM2B AC100/(110) Datasheet - Page 7

no-image

MM2B AC100/(110)

Manufacturer Part Number
MM2B AC100/(110)
Description
RELAY
Manufacturer
Omron
Series
MMr
Datasheet

Specifications of MM2B AC100/(110)

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
15A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Standard
Coil Current
39mA
Coil Voltage
110VAC
Turn On Voltage (max)
88 VAC
Turn Off Voltage (min)
33 VAC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
15A @ 220VAC
Control On Voltage (max)
88 VAC
Control Off Voltage (min)
33 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MM2BAC100/(110)
MM2BAC100110NC
Relays (Conforming to Auxiliary Power Relay Specifications)
Note: 1. The data shown above are initial values.
Engineering Data
■ Standard Relays
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Max. operating frequency
Insulation resistance (See note 4.)
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Error rate (level P)
(Reference value)
(See note 6.)
Ambient temperature
Ambient humidity
Weight
Maximum Switching Power
Open Relays
2. The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.
3. The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute.
of 23°C.
strength.
DC inductive
load L/R = 7 ms
DC resistive load
Switching voltage (V)
Item
MM@(B)
AC inductive
load
(cosφ = 0.4)
AC resistive load
50 mΩ max.
AC: 25 ms max., DC: 50 ms max.
30 ms max.
Mechanical:
Electrical:
100 MΩ min.
Between coil and contact:
Between contacts of different polarity: 2,000 VAC, 50/60 Hz for 1 minute
Between contacts of same polarity:
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 22 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 300 m/s
Malfunction: 30 m/s
Mechanical: 5,000,000 operations min. (at 1,800 operations/hr)
Electrical:
10 mA at 5 VDC
Operating: –10°C to 40°C (with no icing or condensation)
Operating: 5% to 85%
MM4P-JD: approx. 410 g
MM4XP-JD: approx. 420 g
500,000 operations min. (at 1,800 operations/hr with rated load) (see note 5)
1,800 operations/hr
1,800 operations/hr (under rated load)
2
2
Cased Relays
DC inductive
load L/R = 7 ms
2,000 VAC, 50/60 Hz for 1 minute
1,500 VAC, 50/60 Hz for 1 minute
Switching voltage (V)
MM@P(N, -D)
Cased Relays
AC inductive
load
(cosφ = 0.4)
DC resistive load
AC resistive load
MM
7

Related parts for MM2B AC100/(110)