MM4XP-DC100/110 Omron, MM4XP-DC100/110 Datasheet
MM4XP-DC100/110
Specifications of MM4XP-DC100/110
Related parts for MM4XP-DC100/110
MM4XP-DC100/110 Summary of contents
Page 1
... MM2XPN --- MM3XPN --- MM4XPN --- MM4P-JD --- MM4XP-JD Available rated voltage 6, 12, 24, 50, 100/(110), 200/(220) VAC 6, 12, 24, 48, 100/110, 200/220 VDC 100/(110), 200/(220) VAC 6, 12, 24, 48, 200/220 VDC 24, 100/(110), 200/(220) VAC 6, 12, 24, 48, 100/110, 200/220 VDC 100/(110), 200/(220) VAC ...
Page 2
... DC-switching Models Conforming to Auxiliary Power Relay Specifications The MM4P-JD and MM4XP-JD satisfy the ratings of auxiliary relays provided in JEC-2500 (1987) standards for power protective relays specified by the Japan Electromechanical Commission. Furthermore, the MM4P-JD and MM4XP-JD satisfy the ratings of multi-contact relays provided in JEC-174D (1979) standards for power auxiliary relays ...
Page 3
Model Number Legend MM@@@@-@ Contact Form 2: DPDT 3: 3PDT 4: 4PDT 2. Type (See Note.) None: Standard X: DC-switching 3. Terminal Shape None: Solder B: Screw P: Plug-in ■ Accessories (Order Separately) Mounting ...
Page 4
Specifications ■ Coil Ratings Open Coils (with Solder or Screw Terminals) Rated voltage Rated current (mA) ( 790 655 1,120 12 395 325 560 24 195 160 280 134 100/(110) ...
Page 5
... L/R=7 ms) 7 220 VAC VDC 7.5 A 250 VAC, 250 VDC 7.5 A 1,700 VA at 120 W Cased Relays MM2XP(-D), MM3XP, MM4XP(-D) Resistive load Inductive load (cosφ (L/R=7 ms 110 VDC 110 VDC 7.5 A 250 VAC, 250 VDC 7.5 A ...
Page 6
... MM2X approx. 165 g MM2XP approx. 225 g MM3X approx. 275 g MM3XP approx. 395 g MM4X approx. 310 g MM4XP approx. 420 g MM MM4XP-JD Inductive load (cosφ = 0.4, L ms) Cased Relays 6 ...
Page 7
... Operating 85% Weight MM4P-JD: approx. 410 g MM4XP-JD: approx. 420 g Note: 1. The data shown above are initial values. 2. The contact resistance was measured with VDC using the voltage drop method. 3. The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23° ...
Page 8
Endurance Curves Open Relays MM@(B) 10,000 7,000 5,000 220 VAC resistive load 3,000 inductive load (cosφ = 0.4) 1,000 24 VDC 700 resistive load 500 inductive load L 300 100 Switching current (A) ■ DC-switching Relays Maximum ...
Page 9
... DC resistive load DC inductive load L Switching voltage (V) Endurance Curves MM4P-JD 220 VAC: resistive load inductive load cosφ = 0.4 24 VDC resistive load Inductive load L Switching current (A) MM4XP-JD DC resistive load DC inductive load L Switching voltage (V) MM4XP-JD 110 VDC: resistive load inductive load L Switching current ( ...
Page 10
Ambient Temperature vs. Must-operate and Must-release Voltage MM2P AC (60 Hz) Number of Relays: 5 Must-operate voltage Must-release voltage Ambient temperature (°C) Ambient Temperature vs. Coil Temperature Rise MM2P 110 VAC (60 Hz) Contact carry current Number of Relays: 5 ...
Page 11
Relay Mounting Adjacent Distance vs. Coil Temperature Rise MM4P 100 /(110) VAC Relay mounting Upper position Condition: The saturated coil temperature is measured with the rated carry current (7 the rated coil voltage (100 VAC at 50 Hz). ...
Page 12
Mounting Holes (Bottom View) Direct mounting Four, 4.5-dia. mounting holes Length of l 22±0.2 DPDT: 22±0.2 3PDT: 28±0.2 4PDT: 34±0.2 Mounting Bracket (S Bracket) R99-03 (S KANAGU) FOR MM@ The S Bracket can be used to mount a Relay with ...
Page 13
Cased Relays Plug-in Terminals MM2P(N, -D) MM2XP(N, -D) MM2P Note: As shown in the diagram, there are three 10-dia. holes in the side of the case for the MM2XP(N, -D). When a case-protection plate is attached, the width of the ...
Page 14
... MM3PXP(N) MM4P(N, -D) MM4XP(N, -D) 80.5 59.5 max. max. MM4P 79.5 max. (See note 2.) Note 1: As shown in the diagram, there are three 10-dia. holes in the side of the case for MM@XP(N, -D). 2: When a case-protection plate is attached, the width of the Relay will max. Terminal Arrangement (Bottom View) ...
Page 15
... MM4P-JD 70.5 max. 59.5 max. 79.5 max. MM4XP-JD 70.5 max. 59.5 max. 80 max. ■ Relays with Operation Indicators Dimensions are the same as those for standard Relays except that there are three 10-mm holes in the case as shown below. Accessories ■ Sockets Relay model ...
Page 16
Height with Socket DIN Track/Front-connecting Socket MM2(X)P 95.5 MM3P 113 92 109.5 113.5 8PFA 11PFA Safety Precautions Refer to Safety Precautions for All Relays. ■ Connection • Use proper crimp terminals or 1.2- to 2-mm-dia. single-conductor wire to connect screw ...
Page 17
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...