MY2K-US-DC12 Omron, MY2K-US-DC12 Datasheet - Page 3

RELAY

MY2K-US-DC12

Manufacturer Part Number
MY2K-US-DC12
Description
RELAY
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY2K-US-DC12

Rohs Compliant
YES
Contact Form
DPDT
Coil Voltage
12 VDC
Contact Rating
5 A
Contact Termination
Solder Terminal
Mounting Style
Socket
Power Consumption
0.9 W
Contact Material
Silver
Coil Current
75 mA
Coil Resistance
160 Ohms
Coil Type
Standard
Relay Type
General Purpose
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Turn On Voltage (max)
9.6 VDC
Turn Off Voltage (min)
-
Features
-
Mounting Type
Socketable
Termination Style
Plug In
Operate Time
15ms
Release Time
15ms
Coil Power
1.3 W
Operating Temperature
-55°C ~ 60°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ Characteristics
Note: The values given above are initial values.
■ Life Expectancy Characteristics
■ Approved Standards
VDE, UL, CSA, IMQ, CE
■ Precautions
Connections
Do not reverse polarity when connecting DC-operated Relays with
built-in diodes or indicators or high-sensitivity DC-operated Relays.
Mounting
Whenever possible, mount Relays so that it is not subject to vibration
or shock in the same direction as that of contact movement.
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric withstand voltage
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
Pole
2-pole
4-pole
4-pole (bifurcated)
Mechanical life
(at 18,000 operations/hr)
AC:50,000,000 operations min.
DC:100,000,000 operations min.
20,000,000 operations min.
Mechanical 18,000 operations/hr
Electrical
Operating
Operating
100 mΩ max.
20 ms max.
20 ms max.
1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)
Destruction:10 to 55 Hz, 1.0 mm double amplitude
Malfunction:10 to 55 Hz, 1.0 mm double amplitude
Destruction:1,000 m/s
Malfunction:200 m/s
See the following table.
-55°C to 70°C (-67°F to 158°F) with no icing (see note)
5% to 85% RH
Approx. 35 g
2
(approx. 20G)
2
(approx. 100G)
Electrical life
(at 1,800 operations/hr under rated load)
500,000 operations min.
200,000 operations min.
100,000 operations min.
General-purpose Relay
MY
261

Related parts for MY2K-US-DC12