3. Creating a Screen for Each Station
4. Macro Settings
88
Removable Box Application Examples
0
1
2
---
8
Screen number
(4) Click the OK Button to close the System Setting Dialog Box.
Create screens for stations so that the station numbers and the screen numbers match.
Use the following steps to change the screen and notify the PLC of the NSH5's station number based on
changes to the Station Status Monitor Address.
(1) Select Project Properties from CX-Designer's PT Menu.
(2) Click the Macro Tab in the Project Property Dialog Box.
(3) Click the Set Button for the When a bit changed Option.
(4) Perform the following in the When a Bit Changed Dialog Box.
(5) Click the Edit Macro Button next to the When a bit changed Option.
• Select the When a bit changed option.
• Enter $SB1 in the Address Field
• Select the Execute when ON Option in the Action Timing Area.
Initial screen (Displayed when NSH5 is started.)
Screen for Station 1
Screen for Station 2
---
Screen for Station 8
Application
(3) Enter $W1000 for the Station
Status Monitor Address.
Select the option.
Enter $SB1 .
Select the Execute when ON Option
Appendix F