P2R-087P Omron, P2R-087P Datasheet - Page 7

SOCKET / G2R

P2R-087P

Manufacturer Part Number
P2R-087P
Description
SOCKET / G2R
Manufacturer
Omron
Series
G2RSr
Type
Socketr
Datasheets

Specifications of P2R-087P

Mounting Type
Through Hole
Number Of Positions
8
Termination Style
PC Pin
Current Rating
5A
Terminal Type
Pins
No. Of Pins
8
Svhc
No SVHC (15-Dec-2010)
Accessory Type
Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G2R-2-S Relays
For Use With
G2R-2-SNIDC24(S) - RELAY DPDT 24VDC PLUG-IN W/LEDG2R-2-SNIDC12(S) - RELAY DPDT 12VDC PLUG-IN W/LEDG2R-2-SNIAC24(S) - RELAY DPDT 24VAC PLUG-IN W/LEDG2R-2-SNIAC230(S) - RELAY DPDT 230VAC PLUG-IN W/LEDG2R-2-SNIAC120(S) - RELAY DPDT 120VAC PLUG-IN W/LEDG2R-2-SNDIDC24(S) - RELAY DPDT 24VDC PLUG-IN W/LEDG2R-2-SNDIDC12(S) - RELAY DPDT 12VDC PLUG-IN W/LEDG2R-2-SNDDC6(S) - RELAY DPDT 6VDC PLUG-IN W/LEDZ2866 - RELAY PWR DPDT 5A 24VDC PLGG2R-2-SNDC48(S) - RELAY DPDT 48VDC PLUG-IN W/LEDG2R-2-SNAC240(S) - RELAY DPDT 240VAC PLUG-IN W/LEDG2R-2-SNAC230(S) - RELAY DPDT 230VAC PLUG-IN W/LEDG2R-2-SNAC12(S) - RELAY DPDT 12VAC PLUG-IN W/LEDG2R-2-SNAC110(S) - RELAY DPDT 110VAC PLUG-IN W/LEDG2R-2-SDDC6(S) - RELAY DPDT 5A 6VDC PLUG-ING2R-2-SDDC48(S) - RELAY DPDT 5A 48VDC PLUG-ING2R-2-SDDC24(S) - RELAY DPDT 5A 24VDC PLUG-ING2R-2-SDDC12(S) - RELAY DPDT 5A 12VDC PLUG-ING2R-2-SDC5(S) - RELAY GP DPDT 5A 5VDC PLUG-ING2R-2-SDC100(S) - RELAY GP DPDT 5A 100VDC PLUG-ING2R-2-SAC12(S) - RELAY GP DPDT 5A 12VAC PLUG-ING2R-2-SAC110(S) - RELAY GP DPDT 5A 110VAC PLUG-ING2R-2-SND-DC12S - RELAY PWR DPDT 5A 12VDC QC MNTZ2241 - RELAY DPDT 120VAC PLUG-IN W/LEDZ2240 - RELAY DPDT 24VAC PLUG-IN W/LEDZ2239 - RELAY DPDT 24VDC PLUG-IN W/LEDZ2238 - RELAY DPDT 6VDC PLUG-IN W/LEDZ2237 - RELAY DPDT 12VDC PLUG-IN W/LEDZ2231 - RELAY GP DPDT 48VDC PLUG-INZ2229 - RELAY GP DPDT 240VAC PLUG-INZ2225 - RELAY GP DPDT 6VDC PLUG-INZ1639 - RELAY PWR 120VAC 2POL SOCKET MNTZ1638 - RELAY PWR 24VAC 2POLE SOCKET MNTZ1637 - RELAY PWR DPDT 5A 24VDC QC MNTZ1636 - RELAY PWR DPDT 5A 12VDC QC MNT
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
P2R087P
Precautions
■ Correct Use
When using the H3RN in any place where the ambient temperature
is more than 50°C, supply 90% to 110% of the rated voltages (at
12 VDC: 95% to 110%).
Do not leave the H3RN in time-up condition for a long period of time
(for example, more than one month in any place where the ambient
temperature is high), otherwise the internal parts may become dam-
aged. Therefore, the use of the H3RN with a relay as shown in the
following circuit diagram is recommended.
The H3RN must be disconnected from the socket when setting the
DIP switch, otherwise the user may touch a terminal imposed with a
high voltage and get an electric shock.
Do not connect the H3RN as shown in the following circuit diagram
on the right hand side, otherwise the H3RN’s internal contacts differ-
ent from each other in polarity may become short-circuited.
Use the following safety circuit when building a self-holding circuit
with the H3RN and an auxiliary relay, such as a G2R Relay, in combi-
nation.
In the case of the above circuit, the H3RN will be in pulse operation.
Therefore, if the circuit shown on page 3 is used, no auxiliary relay
will be required.
Cat. No. L090-E1-02
T
Correct
X
2
/b
X
1
T/a
X
X
: Auxiliary relay such as G2R Relay
1
/a
X
Incorrect
2
X
1
/a
G2R Relay
Do not use the SPDT contact in a circuit which may cause short-cir-
cuiting at three points (otherwise, short-circuiting of the power supply
may occur) because the SPDT contact of H3RN-1/-11 is composed
of an SPST-NC contact.
Do not set to the minimum setting in the flicker modes, otherwise the
contact may be damaged.
Do not use the H3RN in places where there is excessive dust, corro-
sive gas, or direct sunlight.
Make sure that there is a space of 3 mm or more between any H3RN
Models next to each other. (When using the P2RF-@-E Socket, a
space of 3 mm or more will be secured.) If a space of 3 mm or more
is not secured, the ambient temperature must be less than 50°C.
The internal parts may become damaged if a supply voltage other
than the rated ones is imposed on the H3RN.
■ Precautions for EN61812-1
The H3RN as a built-in timer conforms to EN61812-1 provided that
the following conditions are satisfied.
Handling
Do not touch the DIP switch while power is supplied to the H3RN.
Before dismounting the H3RN from the socket, make sure that no
voltage is imposed on any terminal of the H3RN.
Wiring
Basic insulation is ensured between the H3RN’s operating circuit and
control output.
Basic insulation:
The clearance from the edge of the P2R-087P Socket to internal,
current-carrying metal parts is 1.3 mm. Position the H3RN to provide
the necessary clearance for the voltage used.
When using the P2RF-@-E or P2R-057P Socket, basic insulation is
ensured in the mounted condition for a voltage of 250 VAC max.
Conformance
Power supply
for load
Solid-state timer
Overvoltage category III,
pollution degree 2
(with a clearance of 3.0 mm and a creepage
distance of 3.0 mm at 240 VAC)
Short-circuit current