PYF14A-E-US Omron, PYF14A-E-US Datasheet

SOCKET CLASS 1 DIV 2

PYF14A-E-US

Manufacturer Part Number
PYF14A-E-US
Description
SOCKET CLASS 1 DIV 2
Manufacturer
Omron
Series
MY4Hr
Type
Socketr
Datasheets

Specifications of PYF14A-E-US

Number Of Positions
14
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
MY4H Relays
For Use With
MY4ZH-USDC24 - RELAY GP 4PDT 3A 24VDCMY4ZH-USDC12 - RELAY GP 4PDT 3A 12VDCMY4ZH-USAC24 - RELAY GP 4PDT 3A 24VACMY4ZH-USAC110/120 - RELAY GP 4PDT 3A 110/120VACMY4ZH-DC24 - RELAY GP 4PDT 3A 24VDCMY4ZH-AC24 - RELAY GP 4PDT 3A 24VACMY4ZH-AC110/120 - RELAY GP 4PDT 3A 110/120VACMY4H-USDC100/110 - RELAY GP 4PDT 3A 110/110VDCMY4H-USAC24 - RELAY GP 4PDT 3A 24VACMY4HDC100/110 - RELAY GP 4PDT 3A 100/110VDCZ1225 - RELAY 4PDT 110/120AC HERM SEALEDZ1224 - RELAY 4PDT 24VDC HERM SEALEDZ1223 - RELAY 4PDT 12VDC HERM SEALED
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
PYF14AEUS
Z2650

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PYF14A-E-US
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Miniature Timer with Multiple Time
Ranges and Multiple Operating
Modes
Ordering Information
Connecting Socket
Hold-Down Clips
Panel Adapter
Solid-State Timer
Note:
Supply voltage
24, 100 to 120, 200 to 230 VAC;
12 2
12, 24, 48, 100 to 110, 125 VDC
24 VDC
Applicable Timer
H3YN-2/-21
H3YN-4/-41
H3YN-4-Z/-41-Z
Applicable socket
PYF08A-E, PYF08A-N, PYF14A-E, PYF14A-N
PY08, PY08QN(2), PY08-02, PY14, PY14QN(2), PY14-02
Applicable timer
H3YN-2/21. H3YN-4/41, H3YN-4-Z/41-Z
H3YN -
MODEL NUMBER LEGEND:
ACCESSORIES (ORDER SEPARATELY)
,
Minimize Inventory
Standard multiple operating modes and
multiple time ranges
4PDT or DPDT control output
LED power-ON and time-UP indicators
Sockets, hold-down clips and mounting
accessories may be ordered separately
Specify both the model number and supply voltage when ordering.
8 100
Example: H3YN-2
1
,
2
110 12 VDC
-
3
Track-mounting/front-
connecting socket
PYF08A-E, PYF08A-N
PYF14A-E, PYF14A-N
;
24 VAC
R
1. Output
2: DPDT
4: 4PDT
i
Supply voltage
Time-limit contact
DPDT
4PDT
4PDT (Twin contact)
g/
k
Back-connecting socket
Solder terminal
PY08
PY14
2. Time Range
None: Short-time range (0.1 s to 10 min)
1: Long-time range (0.1 min to 10 hrs)
1
Short-time range model
(0.1 s to 10 min)
H3YN-2
H3YN-4
H3YN-4-Z
Wire-wrap terminal
PY08QN(2)
PY14QN(2)
Part number
Y92H-3
Y92H-4
Part number
Y92F-78
3. Contact Type
None: Single contact
Z: Twin contact
Long-time range model
(0.1 min to 10 h)
H3YN-21
H3YN-41
H3YN-41-Z
PCB terminal
PY08-02
PY14-02
H3YN

Related parts for PYF14A-E-US

PYF14A-E-US Summary of contents

Page 1

... Track-mounting/front- connecting socket i H3YN-2/-21 PYF08A-E, PYF08A-N H3YN-4/-41 PYF14A-E, PYF14A-N H3YN-4-Z/-41-Z Hold-Down Clips Applicable socket PYF08A-E, PYF08A-N, PYF14A-E, PYF14A-N PY08, PY08QN(2), PY08-02, PY14, PY14QN(2), PY14-02 Panel Adapter Applicable timer H3YN-2/21. H3YN-4/41, H3YN-4-Z/41-Z Short-time range model (0 min) H3YN-2 H3YN-4 H3YN-4-Z 2. Time Range None: Short-time range (0 ...

Page 2

H3YN Specifications RATINGS Item H3YN-2/-4/-4-Z Time ranges 0 min ( min min max. selectable) Supply voltage 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 ...

Page 3

H3YN Engineering Data ELECTRICAL SERVICE LIFE Electrical Life Expectancy (Reference Value) H3YN-2/-21 250 VAC, cosφ 5,000 24 VDC, cosφ 1,000 500 200 Load current (A) Reference: A maximum current of 0.6 A can be switched at ...

Page 4

H3YN Nomenclature Output Indicator (Orange) (Lit: Output ON) Main Dial Set the desired time according to time range selectable by DIP switch. Timing Charts Operating mode Timing chart H3YN-2/-21 ON-delay Power (13-14) Power Time limit contact NC (9-1, 12-4) Output ...

Page 5

H3YN PULSE OPERATION A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing charts. H3YN-2/-21 Timer circuit External input H3YN-4/-41 H3YN-4-Z/-41-Z Timer ...

Page 6

H3YN Operation DIP SWITCH SETTINGS The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Time Ranges Model Time range Time setting range H3YN- 0 ...

Page 7

... Unit: mm (inch) TIMERS H3YN-2/-21 Eight 1.2 elliptic holes 52.6 (2.07) 6.4 21.5 max (0.25) 63 (2.48) (0.85) Overall Mounting Depth PYF08E/PYF08A-N PY08 (PY14 see note) (PYF14A/PYF14-N see note) H3YN series 86.6 59.3 (3.41) 90.5 (7.33) (3.56) 20 (0.79) PYF08A-E (PYF14A-E) H3YN-4/-41 H3YN-4-Z/-41-Z 28 max ...

Page 8

H3YN SOCKETS Track-Mounting/Front-Connecting Sockets PYF08A-E Two, 4.2 × 5 3.4 6 mounting holes Eight, M3 × 8 sems 72 max. (2.83) 16.5 23 max. (0.65) (0.91) 30 max. (1.18) PYF-14A-E Two, 4.2 × 5 mounting holes 6 Fourteen, M3 × ...

Page 9

H3YN Back-Connecting Sockets PY08, PY14 Eight, 3 × 1.2 dia. holes only for PY08 (Fourteen, 3 × 1.2 dia. holes) 24 max. (0.94) 0.3 29.5 max 25.5 (1.16) max. 2.6 7.7 27 (0.10) (0.30) (0.11) 20 max. (0.79) PY08QN, PY14QN ...

Page 10

H3YN Y92H-3 Y92H-4 PANEL MOUNT ADAPTER Y92F-78 27.1 48.5 (1.91) (1.07) 33.5 (1.32) MOUNTING TRACK AND ACCESSORIES PFP-100N, PFP-50N 4.5 (0.18 Length 1 m PFP-100N 50 cm PFP-50N 1 m ...

Page 11

... There must be no difference in polarity between any output terminals next to each other of the H3YN-4 or H3YN-41, H3YN-4Z, H3YN-41-Z. OMRON ON- -LINE Global - - http://www.omron.com USA - - http://www.omron.com/oei Canada - - http://www.omron.com/oci S pec ions s ubjec hange w it hout not H3YN OMRON CANADA, INC. 885 Milner Avenue ...

Related keywords