S3D2-CK Omron, S3D2-CK Datasheet

no-image

S3D2-CK

Manufacturer Part Number
S3D2-CK
Description
Sen Ctr
Manufacturer
Omron
Datasheet

Specifications of S3D2-CK

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1
Offers High-speed Input Response of
0.1 ms and Equipped with Built-in
Timer
■ High-speed response of 0.1 ms.
■ Ideal as a two-input Controller.
■ Lineup includes the S3D2-BK with flip-flop functions
■ Power source for the Sensor can be supplied up to
■ Ultra-slim body with 30-mm width.
■ Multi-function model equipped with timer functions also
Ordering Information
* Models compatible with Sensors for PNP connections are also available. These model numbers have the suffix B (e.g., S3D2-AKB)
Differences from NPN Models
Note: S3D2-AK(B)/-CK(B)/-CC(B) models with UL certification are available.
Power supply voltage
100 to 240 VAC
24 VDC
Input signals
Sensor Controller
S3D2
convenient for level control, the S3D2-AKD/CKD/CCD with
24-V power supply, and the S3D2-DK/EK with two inputs/
outputs useful for load control and lamp display.
200 mA.
available.
These model numbers have the suffix US (e.g., S3D2-AK-US).
ON
OFF
Maximum applied voltage
Relay
Transistor
Relay
Transistor
Output
8 to 12 V (2 mA max.)
0 to 4 V (5 mA min.)
Timer function
Yes
Yes
Yes
Yes
Yes
No
No
No
No
12 V
Single-function with two inputs/outputs
Multi-function with two inputs/outputs
Single-function with two inputs/one output
Flip-flop function with two inputs/one output
Multi-function with two inputs/one output
Single-function with two inputs/one output
Multi-function with two inputs/one output
Features
S3D2-DK
S3D2-EK
S3D2-AK
S3D2-BK
S3D2-CK
S3D2-CC
S3D2-AKD
S3D2-CKD
S3D2-CCD
Model
*
*
*

Related parts for S3D2-CK

S3D2-CK Summary of contents

Page 1

... Single-function with two inputs/one output No Flip-flop function with two inputs/one output Yes Multi-function with two inputs/one output Yes No Single-function with two inputs/one output Yes Multi-function with two inputs/one output Yes max min Model S3D2-DK S3D2-EK S3D2-AK * S3D2-BK S3D2-CK * S3D2-CC * S3D2-AKD S3D2-CKD S3D2-CCD ...

Page 2

... AND/OR operating mode • Flip-flop selection function S3D2 Single- function Multi-function (24 VDC) (24 VDC) S3D2-AKD S3D2-CKD S3D2-CCD 24 VDC ± 10% 2.5 VA max. (excluding Sensor power supply) 24 VDC (supplied from power supply max max. 0.5 ms max. NPN open collector output, 30 VDC, 100 mA (NO, ...

Page 3

... Connection Methods S3D2-AK/-AKD S3D2-CK/-CKD INPUT INPUT + + + +12 V POWER OUT POWER OUT S3D2-AK S3D2-CK SENSOR CONTROLLER SENSOR CONTROLLER SOURCE:100 to 240VAC 50/60Hz SOURCE:100 to 240VAC 50/60Hz OUTPUT:3A 250VAC OUTPUT:3A 250VAC RESISTIVE LOAD DC POWER SUPPLY DC POWER SUPPLY 12VDC 200mA OUTPUT OUTPUT COM NO NC COM ...

Page 4

... Note: Numbers in parentheses indicate terminal pin numbers. Contact Output Sensors • The S3D2 has a high-speed input response of 0.1 ms, which may cause contact output models (relay output, micro-switches, etc.) to receive unnecessary input from contact bounce and chattering. Example of Unconnectable Sensor Model ...

Page 5

... ON.* Turns timer operation ON/OFF. ON: Timer enabled OFF: Timer disabled Changes the range for the timer setting time. • S3D2-CK/- Setting time is in range from 0 Setting time is in range from 1 to 10s. • S3D2-CC 0.1 s: Setting time is in range from 0.01 to 0.1s. ...

Page 6

... NORM NORM 5. IN1 and IN2 send AND outputs for T seconds from the falling edge When only one Sensor is connected to the S3D2-CK@ and S3D2-AK/-AKD S3D2-CC@, always set the AND/OR selector switch to MODE OR . AND OR S3D2-DK/-EK: Basic Operation Two Input Signals Output Independently The S3D2-EK is equipped with an OFF-delay Timer ...

Page 7

... S3D2 may cause the insides of protective casing to heat up. S3D2-AKD/-CKD/-CCD • Do not connect a load min. to models for which the S3D2 power supply inputs are to be used as is for the Sensor power supply outputs. Connecting a load min. to the Sensor’s power supply outputs will cause the fuse in the case to break ...

Page 8

... Always lay the S3D2 input lines, output lines, and the power line separately. Otherwise, malfunction due to noise may occur. Output lines (OUT, 100 to 240 VAC) • The power line, through which a large current flows (e.g., to drive a motor) should be wired Provide a distance of 200 mm min. ...

Page 9

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 10

... Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron247.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ...

Related keywords