Monitor Calibration Unit
Operation Instructions
Figure 1. Desco
Description
The Desco
simplify the process of calibrating Workstation Continuous
Monitors. The unit allows the user to quickly and easily
verify whether a tester is operating within specifications. The
Monitor Calibration Unit is a passive device and requires no
power source.
“A Compliance Verification Plan shall be established
to ensure the Organization’s fulfillment of the technical
requirements of the ESD Control Program Plan (ANSI/
ESD S20.20-2007 section 7.3). The product qualification
for the Continuous Monitors per ANSI/ESD S20.20-2007
Table 3 is “User defined” test method and required limits,
and compliance verification is per ESD TR53 with the
required limit being “Manufacturer defined.” Per ESD TR53
Compiance Verification “Compliance verification of the
constant monitor device should follow the manufacturer’s
instructions.”
Packaging
1
1
1
1
1
Calibration Test Procedures
The Monitor Calibration Unit was specifically designed for
use in calibration of Desco brand equipment. The following
step by step procedures will cover calibration for specific test
units. The procedures will not cover adjustment of the test
equipment. For detailed information regarding adjustment of
specific Desco brand testers contact our Customer Service
Department at 909-627-8178.
Monitor Calibration Unit
Alligator Clip
Stacking Snap Banana Jack Adapter
Banana Jack to Wire Adapter
Certificate of Calibration
98220
Rev. December 2009
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website:
98220
Monitor Calibration Unit is designed to
Monitor Calibration Unit
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
TECHNICAL BULLETIN TB-2082
Calibrating the Full Time Continuous Monitor
The Full Time Continuous Monitor is available as following
item number:
TESTING THE OPERATOR CIRCUIT
Step 1: Connect the Calibration Unit’s banana plug wire
labeled “GROUND” to a known ground. Do not plug the
ground lead from the Calibration Unit to the monitor’s
common point ground banana jack. There is a 47 kilohm
resistance to ground.
Step 2: Insert the Calibration Unit’s banana plug labeled
“OPERATOR” into the jack labeled “OPERATOR” on the Full
Time Continuous Monitor (see Figure 2). Power the monitor.
Figure 2. Connecting the OPERATOR test lead from
the Monitor Calibration Unit to the Full Time Continuous
Monitor
Step 3: Start the Calibration Unit’s selector knob at the full
counter-clockwise position. When testing the OPERATOR
circuit, test only the first four limits on the Calibration Unit.
Rotate the selector knob to the “LOW FAIL” position; the
red “OPERATOR GROUND” LED on the monitor should
illuminate and alarm.
Item
19225
Voltage
120 VAC
Desco.com
© 2009 DESCO INDUSTRIES, INC.
Made in America
Employee Owned

98220 Summary of contents

Page 1

... Monitor Calibration Unit Description The Desco Monitor Calibration Unit is designed to 98220 simplify the process of calibrating Workstation Continuous Monitors. The unit allows the user to quickly and easily verify whether a tester is operating within specifications. The Monitor Calibration Unit is a passive device and requires no power source. “ ...

Page 2

... LED should illuminate. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: TB-2082 Page Calibrating the Dual Operator Continuous ...

Page 3

... LED should illuminate. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: TB-2082 Page Note: During FAIL LOW and FAIL HIGH, the monitor will continuously alarm until the banana lead is removed from the satellite remote ...

Page 4

... DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: TB-2082 Page Calibrating the Multi-Mount Continuous Monitor ...

Page 5

... Hi Fail 44.7 pF 0.192 Mat (tolerance = ± 4%): Pass Fail 10 Meg 8 Megohms 12 Megohms 100 Meg 80 Megohms 120 Megohms 500 Meg 400 Megohms 600 Megohms Desco.com MAT 98220 High Fail Dis Cp Dis Megohms @ 50V V Measure ~ 50 © 2009 DESCO INDUSTRIES, INC. Employee Owned ...

Page 6

... Limit of Liability In no event will Desco or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • ...