HMS 10-P LEM USA Inc, HMS 10-P Datasheet

SENSOR CURRENT 10A 5V UNI SMD

HMS 10-P

Manufacturer Part Number
HMS 10-P
Description
SENSOR CURRENT 10A 5V UNI SMD
Manufacturer
LEM USA Inc
Datasheets

Specifications of HMS 10-P

Current - Sensing
10A
Accuracy
±1%
Sensitivity
-
Current - Supply
19mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
5V
Output
-
Frequency
50kHz
Response Time
5µs
Polarization
Bidirectional
Operating Temperature
-40°C ~ 85°C
Package / Case
0.02" (0.51mm) Round
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
398-1059-6
Current Transducer HMS 5..20-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
V
G
V
R
R
C
V
I
X
e
TCV
TCV
TCV
TCG
V
V
t
t
di/dt
V
BW
Notes :
110512/13
Primary nominal
C
ra
r
OUT
REF
C
L
OE
OM
no
L
OUT
L
TH
current rms
OUT
Electrical data
Accuracy - Dynamic performance data
OUT
REF
/V
I
10
15
20
REF
PN
5
Output voltage (Analog) @ I
Theoretical sensitivity
Reference voltage
Load resistance
Output internal resistance
Capacitive loading
Supply voltage (± 5 %)
Current consumption @ V
Accuracy
Linearity error 0 .. I
Temperature coefficient of V
Temperature coefficient of V
Temperature coefficient of V
Temperature coefficient of G
Electrical offset voltage @ I
Magnetic offset voltage @ I
after an overload of 3 x I
Reaction time @ 10 % of I
Response time to 90 % of I
di/dt accurately followed
Output voltage noise (DC .. 10kHz)
Frequency bandwidth (- 3 dB)
(A)
1)
2)
3)
4)
It is possible to overdrive V
between 1.5V - 2.8V providing its ability to sink or source approximately
5 mA.
Excluding offset and hysteresis.
Maximum supply voltage (not operating)
Small signal only to avoid excessive heatings of the magnetic core.
2)
@ I
measuring range
Primary current
PN
.. 3 x I
V
V
, T
± 15
± 30
± 45
± 60
REF
REF
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
1)
I
PM
PN
A
- Output voltage
= 25°C
Output impedance
Load impedance
(A)
(DC .. 1MHz)
3)
PN
PN DC
C
PN
PN
P
P
= 5 V
P
OUT
REF
OUT
= 0, T
= 0,
step
REF
4)
/ V
@ I
(25 .. 85 °C)
(-40 .. 25 °C)
with an external reference voltage
REF
A
P
Primary Conductor
= 25℃
= 0
@ I
0.65 x 1.6 x 4T
0.65 x 1.6 x 4T
1.2 x 2.2 x 2T
1.2 x 2.2 x 2T
Size x Turns
P
= 0
(mm)
All data are given with a R
< 6.5 V
typ. 200
V
0.625
2.5 ± 0.025
≥ 200
≥ 2
< 5
= 4.7
19
≤ ± 1
≤ ± 0.5
≤ ± 1
≤ ± 0.4
≤ ± 0.01
≤ ± 0.015
≤ ± 0.2
≤ ± 0.07 % of reading/K
V
< ± 1.2
< 3
< 5
> 50
< 20
< 40
DC .. 50
5
OE
REF
± (0.625·I
± 0.025
HMS 05-P
HMS 10-P
HMS 15-P
HMS 20-P
Type
L
% of I
% of I
% of I
% of I
= 10 k
P
mVpp
mVpp
/I
mV/K
mV/K
V/I
A/µs
PN
%/K
%/K
kHz
mA
kW
kW
nF
) V
µs
µs
PN
PN
PN
PN
PN
W
W
V
V
V
W
I
Features
● Hall effect measuring principle
● Galvanic isolation between
● Isolation test voltage 4300V
● Low power consumption
● Extremely low profile, 12mm
● Single power supply +5V
● Fixed offset & gain
● For SMT mounting
Advantages
● Small size and space saving
● Only one design for wide primary
● High immunity to external
● V
Applications
● AC variable speed drives
● Static converters for DC motor
● Battery supplied applications
● Uninterruptible Power Supplies
● Switched Mode Power Supplies
● Power supplies for welding
Application domain
● Industrial
PN
primary and secondary circuit
current range
interference.
modes
drives
(UPS)
(SMPS)
applications.
REF
= 5 .. 20 A
pin with REF OUT & REF IN
www.lem.com
Page 1/6

Related parts for HMS 10-P

HMS 10-P Summary of contents

Page 1

... LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. All data are given with a R Primary Conductor Type Size x Turns (mm) HMS 05-P 0. 0. HMS 10-P 1 HMS 15-P 1 HMS 20-P V ± (0.625·I OE 0.625 2.5 ± ...

Page 2

Current Transducer HMS 5..20-P General data T Ambient operating temperature A T Ambient storage temperature S m Mass UL94 Classification Standard Isolation characteristics V Rated isolation voltage rms b with IEC EN 50178, 61010-1 standards and following conditions Over voltage ...

Page 3

... Vout Vref.(IN/OUT TURNS 0V 0. 1 TURNS HMS 05-P 0.65 t 1.6 w HMS 10-P HMS 15-P 1.2 t 2.2 w HMS 20-P (*) 0deg ( ax. ) 245 +/- 5deg deg / /-15sec 180 +/- b-free reflow profile 180d deg/ sec (*) 260 0deg ( ax. ) Tim deg / /-15sec 180 +/- ...

Page 4

Current Transducer HMS 5..20-P Handling Instructions Notes for Storage, Handling and Mounting the transducer Storage (1) General storage conditions: Temperature °C Humidity %RH without dew condensation (2) Storage period: Storage period is within 1 ...

Page 5

This Specification is according to JIS C 0806-3, EIA-481-D (more than 2000mm) 110512/13 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 28±0.1 Page 5/6 www.lem.com ...

Page 6

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 6/6 www.lem.com ...

Related keywords