MF010-0-LC1 Honeywell Sensing and Control, MF010-0-LC1 Datasheet

no-image

MF010-0-LC1

Manufacturer Part Number
MF010-0-LC1
Description
GAS SENSORS
Manufacturer
Honeywell Sensing and Control
Series
-r
Type
Oxygenr
Datasheet

Specifications of MF010-0-LC1

Oxygen Range
1 mbar ~ 250 mbar
Accuracy
±2%
Output
0 ~ 10 V
Operating Temperature
-10°C ~ 50°C
Voltage - Supply
22.8 V ~ 25.2 V
Current - Supply
500mA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MF010 Series Low
Temperature and
MF020 Series High
Temperature
Oxygen Sensors
DESCRIPTION
The MF010 Series Low Temperature Oxygen Sensors is
designed to determine the oxygen concentration in air or inert
gas mixtures with temperatures of -100 °C to 250 °C [-148 °F
to 482 °F] max. The MF020 Series High Temperature Oxygen
Sensors is designed to determine the oxygen concentration in
air or inert gas mixtures with temperatures of -100 °C to 400 °C
[-148 °F to 752 °F] max.
These products are particularly suitable for measuring oxygen
in areas that are not easily accessible, or in closed systems.
The MF010 and MF020 Series may both be supplied with a
measuring range of 0.1 vol%O
to 100 vol%O
both series.
The sensor detects the gas mixture’s oxygen partial pressure
(absolute oxygen content) by using a dynamic process that
occurs on two zirconium dioxide discs which form a
hermetically sealed chamber. Because no chemical
substances are used, the sensor exhibits significantly longer
service life than an electrochemical sensor.
The actual oxygen sensor is mounted in the tip of the bar
probe and is protected by a stainless-steel sintered disk which
serves as a flame back-flash stop. The water-proof plastic
housing accommodates the electronics and is mechanically
connected to the bar probe.
FEATURES
No moving parts
Low power consumption
No need for temperature stabilization
Functional testing and calibration in ambient air
Long life
2
. The entire measurement range is linear for
2
to 25 vol%O
2
and 0.1 vol%O
2
Sensor electronics include:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Internal potentiometer
The sensor outputs the measured values via an analog
channel (4 mA to 20 mA or 0 V to 10 V) and a digital channel
(also provides any error signals) which are evaluated and
further processed in a user-specified external mounting device
such as a fuel controller, display, measuring instrument,
programmable logic controller or ventilation system.
Both series may be calibrated manually or self-calibrated using
atmospheric air instead of a reference gas. The sensor can
also conduct external operational self-tests.
Both series may also operate in a fault-proof mode. The sensor
self-monitors during operation and provides error signal output.
A second oxygen sensor is not necessary.
POTENTIAL APPLICATIONS
Boiler combustion controls
Aircraft oxygen generation systems
Signal amplifier
Control for the ionic pump with an analog component
Test component
Internal monitoring logic component
Power supply for the sensor heating element and the
analog and digital components
Reset
Voltage monitor
Analog output
Bi-directional digital output

Related parts for MF010-0-LC1

MF010-0-LC1 Summary of contents

Page 1

... These products are particularly suitable for measuring oxygen in areas that are not easily accessible closed systems. The MF010 and MF020 Series may both be supplied with a measuring range of 0.1 vol vol 100 vol%O ...

Page 2

... MF010 Series and MF020 Series Table 1. MF010 Series Specifications and Order Information Characteristic MF010-0-LC1 MF010-1-LC1 MF010-2-LC1 Temperature range at probe tip Output O range (O partial pressure) 1 mbar to 250 mbar 2 2 with equivalent O output 0.1 vol%O 2 Probe length: -0-LXX -1-LXX -2-LXX Table 2. MF020 Series Specifications and Order Information ...

Page 3

... Vdc 5 Channel Vol mA Vol%O 6 Channel 2 (I/O) calibration switch ground 7 Partition Atmospheric Air 50 °C [122 °F] Max. 250 °C [482 °F] Max. (MF010) Housing 400 °C [752 °F] Max. (MF020) 15° Bar Probe Honeywell Sensing and Control Gas Mixture 3 ...

Page 4

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or ...