RP-LS42F-75L BANNER ENGINEERING, RP-LS42F-75L Datasheet

no-image

RP-LS42F-75L

Manufacturer Part Number
RP-LS42F-75L
Description
42MM ROPE PULL SAFETY INTERLOCK
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheet

Specifications of RP-LS42F-75L

Actuator Type
Latch
Body Style
Rectangular
Current, Rating
50 mA
Ip Rating
IP67
Number Of Positions
2
Voltage, Rating
10-30 VDC
Printed in USA
• Contacts latch open when rope is pulled; requires manual reset
• Heavy-duty thermoplastic housing, rated IP67 and NEMA 4, suitable
• Innovative design provides quick, easy rope fixing and tensioning on models
• Rope spans up to 75 m (245')
• Both safety contacts are closed with normal rope tension, and open when rope is
• Extra contacts for monitoring or to provide dual-channel input to a safety module
• Indicator mark on switch shows when rope has proper tension for operation
• Long life, switch rated at 1 million mechanical operations, minimum
• Three available models: one with E-stop button, all with latching outputs
Rope Pull Emergency Stop Switches
RP-LS42F-75L.. Series 42 mm Latching Switches with Rope Actuators
upon springs
for demanding industrial environments
RP-LS42F-75LE and RP-LS42F-75LF
pulled or if rope breaks (or if tension is reduced from normal amount)
Insulated device (IEC 60947-5-1) on all models with plastic housings
Positive-opening safety contacts (IEC 60947-5-1), not dependent
07/06
Features
P/N 67709 rev. A

Related parts for RP-LS42F-75L

RP-LS42F-75L Summary of contents

Page 1

... Printed in USA Rope Pull Emergency Stop Switches RP-LS42F-75L.. Series 42 mm Latching Switches with Rope Actuators • Positive-opening safety contacts (IEC 60947-5-1), not dependent upon springs • Contacts latch open when rope is pulled; requires manual reset • Heavy-duty thermoplastic housing, rated IP67 and NEMA 4, suitable for demanding industrial environments • ...

Page 2

... Machinery—Emergency Stop Equipment Functional Aspects, Principles for Design” IEC 60947-5-5 “Electrical Emergency Stop Devices with Mechanical Latching Function” Available from: 2 P/N 67709 rev. A RP-LS42F-75L.. Series Application Assistance Toll Free: 1-888-3-SENSOR (1-888-373-6767) Email: sensors@bannerengineering.com Address: 9714 Tenth Avenue North ...

Page 3

... Models RP-LS42F-75L.. are rope pull emergency stop switches in compact, limit switch- style housings made of high-impact thermoplast. When used with steel wire rope, they can provide emergency stop actuation along conveyors and similar machinery. Red PVC-covered 3 mm diameter wire rope is recommended (see page 10). ...

Page 4

... Use pulleys (recommended) or eye bolts at each support point. A pulley must be used when routing the rope around a corner, regardless of the angle. 4 P/N 67709 rev. A RP-LS42F-75L.. Series Figure 2. Tightening the rope into the internal turnbuckle (models RP-LS42F-75LE and RP-LS42F-75LF) Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 ...

Page 5

... Model RP-LS42F-75L: Turn the turnbuckle until the arrows are centered. Models RP-LS42F-75LE and RP-LS42F-75LF: Turn the shaft of the switch using wrench as shown in Figure 4, until the arrows are centered. Pull hard on the rope and reset the latch several times. If the arrows in the tensioning ...

Page 6

... Dual-Channel Output: Wire contacts 21/22 and 41/42 independently to the two safety module inputs (see Figure 6).  P/N 67709 rev. A desired wiring terminal. terminal jaws; insert wire. RP-LS42F-75L.. Series Dual-Channel Safety Device CH 2 Figure . Wire the two switch contacts in series Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 ...

Page 7

... Models RP-LS42F-75L and RP-LS42F-75LF: Pull the blue reset button; the arrows should then be centered in the tensioning indicator window. Model RP-LS42F-75LE: The E-stop can be reset only when proper tension is indicated. Turn the yellow knob clockwise until the blue arrow is in the “I” position (indicating that the latch has been reset) ...

Page 8

... Adapter supplied to convert M20 x 1.5 to ½" NPT threaded entrance Construction High-impact thermoplastic housing; zinc die-cast actuator Environmental Rating NEMA 4, IEC IP67 Operating Conditions Temperature: Weight RP-LS42F-75L: 0.48 Kg (1.05 lbs.) RP-LS42F-75LE: 0.65 Kg (1.43 lbs.) RP-LS42F-75LF: 0.65 Kg (1.43 lbs.) Certifications 8 P/N 67709 rev. A RP-LS42F-75L.. Series Specifications AWG (1 AWG (1 ...

Page 9

... RP-LS42F-75LE 256.0 mm (10.08") 88.0 mm (3.46") Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 Dimensions RP-LS42F-75L 124.0 mm (4.88") 45.0 mm 5.0 mm (1.77") (0.20") 42.0 mm 78.3 mm (1.65") (3.08") 294.0 mm (11.57") RP-LS42F-75L.. Series 224.0 mm (8.82") 30.0 mm (1.18") RP-LS42F-75LF 78.3 mm (3.08") P/N 67709 rev ...

Page 10

... Clamp Thimble NOTE: If model RPA-S4-1 tensioning spring is used, eliminate eye bolt, spring, protector cable, clamp and thimble from versions shown here. Figure 7. Wire rope assembly components 10 P/N 67709 rev. A RP-LS42F-75L.. Series Description Turnbuckle Pulley Pulley Thimble Spring Spring breakage Spring ...

Page 11

... Switch Models Diameters 6.0 to 12.0 mm All (0.24" to 0.47") Conduit Adaptors Used with Thread Switch Models Conversion M20 x 1.5 to All ½" -14 NPT RP-LS42F-75L.. Series Dimensions 37.0 mm 25.0 mm (1.46") (0.98") M20 x 1.5 Dimensions 23.0 mm 1/2"-14 NPT (0.91") Internal Thread M20 x 1.5 O-ring P/N 67709 rev ...

Page 12

... Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 67709 rev. A Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com RP-LS42F-75L.. Series ...