E5-648-C4461 EATON CUTLER HAMMER, E5-648-C4461 Datasheet - Page 5

no-image

E5-648-C4461

Manufacturer Part Number
E5-648-C4461
Description
PRESET COUNTER, 6-DIGIT, 90VAC TO 260VAC
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-648-C4461

No. Of Digits / Alpha
6
Digit Height
9mm
Supply Voltage Range
90VAC To 260VAC
Power Consumption
750VA
Counting Speed
50kHz
Operating Temperature Range
-20°C To +65°C
E5-648-C446x electronic preset
counter with four presets (relays)
LCD negative, red-green backlighting
7.4 Selecting the menu items
7.5 Setting the menu items
7.6 Accepting the setting
7.7 Ending the programming
During programming, it is possible to exit the programming
at each menu item by pressing the reset key.
The Prog/Mode key is used to select
a menu item within the sub-menu
When setting count values, each decade
has a key assigned to it. Each time the key
is pressed, the value increments by one
Pressing the Prog/Mode key causes
the current setting to be accepted.
Programming then switches to the
next menu item
The security prompt appears in the display
Pressing the Prog/Mode key acknowledges
this prompt and causes the programming
menu to start again from the beginning.
The previously programmed values are
preserved. These can now be changed
or checked again
Pressing the decade key T2 selects the
termination of the programming
The security prompt appears in the display
Pressing the Prog/Mode key
acknowledges this prompt and
terminates the programming; the modified
settings are saved in the EEPROM
The text SAVE is displayed for 2s
Press the Reset key
The T2 key is used to select the individual
settings for the menu items
7.8 Programming menu
7.8.1 Default parameters
Three default parameter sets have been permanently stored;
these can be adapted as required. With each acknowledgment
of the parameter sets, all parameters will be reset to the values
listed in the table.
The dEFAuL P .USEr can be freely programmed.
7.8.2 Parameter sets
Factory settings are highlighted in grey
Display
Func
InP.PoL
FiLtEr
Count
MPi
Loc.InP
ModE
FActor
diViSo
dP
SEtPt
CoLor
rESmd
Pr.Out 1
t.Out 1
Pr.Out 2
t.Out 2
Pr.Out 3
t.Out 3
Pr.Out 4
t.Out 4
eaton corporation www.eaton.com
p .Set 1
Count
PnP
on
Cnt.dir
LAtch
ProG
Add
01.0000
01.0000
0
000000
red.Grn
Man.EL
Menu Parameter sets
Default setting
Parameter set 1
Default setting
Parameter set 2
Default setting
Parameter set 3
Freely programmable
User settings
Instruction leaflet IL05407001E
p .Set 2
Count
PnP
oFF
uP.dn
LAtch
ProG
Sub
01.0000
01.0000
0
000000
red.Grn
Man.EL
00.10
00.10
00.10
00.10
Effective October 2010
p .Set 3
Count
PnP
oFF
Quad
Set
ProG
AddAr
01.0000
01.0000
0.00
0000.00
red.Grn
Man.EL
00.10
5