81550001 Crouzet USA, 81550001 Datasheet - Page 37

SEQUENCER MODULES

81550001

Manufacturer Part Number
81550001
Description
SEQUENCER MODULES
Manufacturer
Crouzet USA
Datasheet

Specifications of 81550001

External Width
49mm
External Depth
32mm
Operating Pressure Max
120psi
Features
Maintained PAC Sequencer
External Height
51.3mm
Operating Pressure Min
30psi
For Use With
Pneumatic Logic Components
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Part numbers
Versions
Symbol
Characteristics
Operating pressure
Orifice diameter
Flow at 90 PSI (6 bars)
Connection - sub-base page 5/44 - 5/45
Weight
Principle of operation
(supplied without logic element. For choice of units see page 5/36 - 5/37 - 5/39 - 5/40 - 5/42)
Dimensions
Sequencer modules
Programmable Air Controller (PAC) module with maintained reset
1-1/4"
(32)
PAC sequencer
shift register
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-15/16"
(49)
Other information
1 - Input signal
2 - Supply
3 - Output signal
4 - Start signal
5 - In cycle signal
6 - End of cycle signal
7 - Reset to zero signal
psi
Inches
cfm
Products and specifications subject to change without notice.
(bar)
(mm)
(Nl/min)
grams
81 550 001
30 > 120
0.106”
5.25
(70)
maintained
-
Shift register with maintained reset
(2 > 8)
(2.7)
(150)
Mounting plan for sequencer
0.146" (3.7)
0.130" (3.3)
2 Holes M4
min depth 9/32" (7)
0.598" (15.2)
81 550 201
30 > 120
0.106”
5.25
(70)
0.563" (14.3)
6 Holes Ø 0.118" (3) 1 Hole Ø0.110" (2.8)
Standard products
Standard products,
non stocked
Auto Reset
0.276" 0.276"
(7)
-
PSI
60
45
30
18
1 Hole Ø3/32" (4)
(2 > 8)
(2.7)
(150)
(1,25)
0.354"
(bar)
(4,5)
(3,5)
(2,5)
(1,5)
(0,7)
(0,5)
(7)
(4)
(3)
(2)
(1)
(9)
0
Minimum pressure to be applied to ports 1-4-7
to switch the valve
To order, specify :
(1)
15 30 45 60 75 90 105 120
(2)
1 - Input signal
2 - Supply
3 - Port plugged
4 - Input signal
5 - Port plugged
6 - Output signal
7 - Reset to zero signal
81 550 601
30 > 120
0.106”
5.25
(70)
Use (metric) dimensions for critical data.
(3)
Auto Reset
Example : Sequencer modules 81 550 001
(4)
1
(5)
-
Part number
(6)
(2 > 8)
(2.7)
(150)
(7)
(8)
supply pressure
(bar)
PSI
5/33
1
5

Related parts for 81550001