3-520276-2 TE Connectivity, 3-520276-2 Datasheet

TERMINAL, FEMALE DISCONNECT 0.187IN BLUE

3-520276-2

Manufacturer Part Number
3-520276-2
Description
TERMINAL, FEMALE DISCONNECT 0.187IN BLUE
Manufacturer
TE Connectivity
Type
Quick Disconnect Terr
Series
Ultra-Fast FASTONr
Datasheet

Specifications of 3-520276-2

Tab Size
3.86mm²
Wire Gauge
14-16
Body Plating
Tin
Body Material
Brass
Gender
RCP
Insulation
Nylon
Product Depth (mm)
8.53mm
Product Length (mm)
23.75mm
Color
Blue
Connector Type
Female Disconnect
Insulator Color
Blue
Termination Method
Crimp
Stud/tab Size
0.187 X 0.032"
Wire Size (awg)
16-14
Contact Material
Brass
Rohs Compliant
Yes
Terminal Type
Receptacle
Proprietary Name
Ultra-Fast
Receptacle Style
Straight
Mating Area Interface Dimensions (mm [in])
4.75 x 0.81 [.187 x .032]
Insulation Diameter (mm [in])
6.60 [.260] Max.
Insulation Support
Non-Insulation Support
Finish
Tin
Wire Range (mm [awg])
1.25-2.00² [16-14]
Fully Insulated
Yes
Ul Flammability Rating
UL 94V-2
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Strip
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
3-520276-2
Manufacturer:
TE
Quantity:
20 000
86
Product Facts
Performance Capabilities
Catalog 82004
Revised 10-07
www.tycoelectronics.com
One-piece Fully Insulated
Premier Line FASTON
Receptacle crimp helps
prevent shock and short
hazards
Designed for correct lead-in
of tab
Designed for full mating
with a variety of tab styles
including those with
shoulders
Funnel wire entry
Wire Stop
Visual inspection of crimp
and wire brush
Assemblies are color-coded
by wire size
Assemblies contain wire
size and tab size
designation
Mating tab thickness
marked on terminal and
visible through housing
(.110, .187 and .205 Series)
Application tooling
available to meet
production requirements
Tin plated copper alloy
terminals
UL rated at + 105°C
Terminates 26-10 AWG
solid, fused and stranded
wire (Flags terminate
stranded wire only)
Meets UL-310 specification
for quick connect terminals;
UL listed under
File No. E-66717
Meets CSA C22.2, No. 153
specification for quick
connect terminals;
CSA Certified under
File No. LR 7189
VDE tested according to DIN
VDE 0627/9.91, specification
for connectors and plug and
socket devices,
VDE Reg. No.
600-volt application
capability (1,000 volts for
signs and fixtures)
R
are metric equivalents.
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
R
FASTON Terminals (Insulated and Uninsulated)
Ultra-Fast Fully Insulated FASTON Receptacles and Tabs
The Ultra-Fast Fully Insulated
FASTON Receptacle and
Tab offers the advantage of
a completely protected
terminal and a wire crimp
with comparable
electromechanical
performance to open barrel
“F” crimp FASTON Terminals.
The “User-Friendly” design
combines easy mating with
rounded corners. The .187
and .250 series receptacles
incorporate a two-stage roll
configuration and a canti-
lever mounted dimple which
provides easy insertion and
multiple independent points
of contact for reduced tab
interface resistance.
Ultra-Fast Fully Insulated
FASTON Receptacles,
Flag Receptacles and Tabs
preclude the need for costly
electrical safety interlocks or
special protective shields to
help prevent shock hazards.
In addition, electrical short
circuits from exposed leads
are eliminated, even in
equipment requiring close
contact spacing.
The Ultra-Fast FASTON
Receptacle, Flag Receptacle
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
and Tab are preinsulated
assemblies featuring a
housing molded from
type 6/6 nylon material
with a +130°C UL
temperature rating.
The Ultra-Fast FASTON
Receptacle housing
completely encloses a tin
plated copper alloy Premier
FASTON receptacle which
has been stress-relieved for
increased durability and
resistance to abuse. The
FASTON receptacle is
recessed sufficiently within
the housing to allow its use
in 600-volt applications. The
receptacle portion of the
terminal is designed for
positive mating with a variety
of tabs, including those with
shoulders. The housing has
a slotted membrane which
is displaced by two tab
shoulders allowing proper
engagement of tab and
receptacle while maintaining
the fully insulated
characteristic.
Positive entry and lead-in of
the tab is provided by the
inner housing wall and the
lead-in on the terminal rolls.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
This permits positive
engagement, even in blind
mating locations.
The Ultra-Fast FASTON
Tab housing completely
encloses a tin plated copper
alloy FASTON tab. The
FASTON tab is recessed
sufficiently within the
housing to allow its use in
600-volt applications. The
housing is designed to
completely encapsulate the
tab and receptacle when the
two are mated.
Quality control is easily
maintained. The nylon
housing is translucent,
allowing visual inspection of
the termination. In addition,
a crimp code on the platform
hand tool is indented into the
housing during the crimping
operation which identifies
that the proper crimp dies
were used.
Depending on
production requirements,
Tyco Electronics provides
a complete selection of
terminating equipment from
hand tools to automatic
lead makers.
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208

Related parts for 3-520276-2

3-520276-2 Summary of contents

Page 1

... UL listed under of contact for reduced tab File No. E-66717 interface resistance. R Meets CSA C22.2, No. 153 ■ Ultra-Fast Fully Insulated specification for quick FASTON Receptacles, connect terminals; Flag Receptacles and Tabs CSA Certified under ...

Page 2

... In the testing of the Ultra-Fast FASTON product applied to 16 AWG wire, the temperature rise was found to be below 10°C at the rated current. In fact, the temperature rise did not exceed 30°C until the current was above 20 amps, more than twice the rated current. Current Cycling vs. Temperature Rise (16 AWG) ...

Page 3

... Brass 2-520261-2 3 2-520262-2 Brass 2-520274-2 3 2-520275-2 Brass 3-350815-2 3 3-350816-2 Brass 3-520124-2 3 3-520125-2 Brass 3-520150-2 3 3-520151-2 Brass 3-520276-2 3 — Brass 2-521406-2 3 — Brass 2-521308-2 3 — Brass 2-520183-2 3 2-520184-2 Phos. Brz. 2-520183-4 3 2-520184-4 Brass 2-520263-2 3 2-520264-2 Phos. Brz. 2-520263-4 3 — Brass ...

Page 4

... 4.75 8.13 6.48 16.05 13.08 .032 x .187 0.81 x 4.75 16-14 .020 x .187 0.51 x 4.75 .260 .187 .320 .325 .668 .565 6.60 4.75 8.13 8.26 16.97 14.35 .032 x .187 0.81 x 4.75 .165 .187 .385 .235 .636 .580 .032 x .205 22-18 4.19 4.75 9.78 5.97 16.15 14.73 0.81 x 5.21 ...

Page 5

... Insulated FASTON wire Receptacles and Tabs ■ Complies with the IEC preclude the need for costly 380, 601, 950, and UL electrical safety interlocks 1950 requirements for a or special protective shields secondary means of to help prevent shock insulation fixing hazards ...

Page 6

... .020 x .110/.125 0.51 x 2.79/3.18 .060-.120 .160 .275 .167 .735 22-18 1.52-3.05 4.06 6.99 4.24 18.67 .032 x .110/.125 0.81 x 2.79/3.18 .020 x .187 0.51 x 4.75 .060-.135 .165 .336 .200 .855 22-18 1.52-3.43 4.24 8.53 5.08 21.72 .032 x .187 0.81 x 4.75 ...

Related keywords