312-KEG 3M Interconnect Solutions, 312-KEG Datasheet

no-image

312-KEG

Manufacturer Part Number
312-KEG
Description
Manufacturer
3M Interconnect Solutions
Type
Wire Jointr
Datasheet

Specifications of 312-KEG

Wire Gauge
10-22
Gender
F
Insulation
Nylon
Product Depth (mm)
18.4mm
Product Length (mm)
26.2mm
Color
Yellow
Lead Free Status / RoHS Status
Supplier Unconfirmed
Insulated Electrical Spring
Connector 312
Data Sheet
Application:
Use a 312 connector to electrically connect two or more wire
ends in a pigtail application and insulate the connection, or to
insulate a single wire end.
Wire Range:
AWG Range
COPPER conductors only, No. 22 thru No. 10 solid or
stranded wire.
METRIC Range
COPPER conductors only, 0.75 mm
(solid or stranded) and flexible.
(See wire matrix for specific wire combinations.)
Construction:
Spring
Insulator
Weight:
0.004 lb. (1.8 gm)
Abbreviations:
UL: Underwriters Laboratories
AWG: American Wire Gauge
CU: Copper sol.: solid, str.: stranded, mm: millimeters,
mm
lb.: pound
Engineering Specification:
Electrical Spring Connector (3M
capable of connecting wires within the range of No. 22 thru
No. 10 solid or stranded copper conductors, in a pigtail
application. The connector shall constructed of an active
(live) spring and covered by a nylon insulator. The spring
shall have a corrosion resistant coating. The connector shall
be UL Listed as a pressure cable connector, and be CSA
Certified. The connector shall be voltage rated 600 volts
maximum, building wire, 1000 volts maximum, signs,
fixtures and luminaries. The connector shall have a
maximum operating temperature of 105 C.
C: degrees Celsius, F: degrees Fahrenheit, gm: gram,
2
: square millimeters,
–Spring steel, Corrosion resistant coating
–Flame retardant nylon, Color–Yellow
part No. 312) shall be
2
thru 4,0 mm
2
rigid
Regulatory Agencies:
U.L. Listed — as a Pressure Cable Connector
Tested per UL Standard 486C
U.L. File No. E23438
Federal Specification W–S–610:
Commercial Package Only
OPERATING TEMPERATURE: 105 C (221 F)
VOLTAGE RATING: 600 volts maximum building wire;
Type
LISTED 540H
1
1000 volts maximum in signs and lighting fixtures
(luminaries).
Class
3M File NO. E95240
685–1 and 685–2–4
IEC Publications
1
Kind
cu
3M File NO. LR15503
Canadian Standards
Standard NO. 22.2
NO. 188–M1983
Association
Style
G

Related parts for 312-KEG

312-KEG Summary of contents

Page 1

... Insulated Electrical Spring Connector 312 Data Sheet Application: Use a 312 connector to electrically connect two or more wire ends in a pigtail application and insulate the connection insulate a single wire end. Wire Range: AWG Range COPPER conductors only, No. 22 thru No. 10 solid or stranded wire. ...

Page 2

... Conductor Size 22 –16 AWG (0,75 – 1 – 8 AWG (2,5 – 4,0 mm — 2 — LISTED 540H HOW TO READ THIS CHART EXAMPLE 1: 2 No. 16 sol + 4 No. 16 sol (=6) may be connected using a 312 connector EXAMPLE 2; 3 No. 14 str + 1 No. 14 str (=4) may be connected using a 312 connector ...

Page 3

Metric Wire Combinations International Electrotechnical Commission Rated Capacity: 1,5 – 10,0 mm Voltage rating: 600 volts maximum Reusability: Reusable for same capacity or larger Wire Type: Copper only See installation instructions for conductor strip lengths I.E.C. Metric Wire Matrix: Twist-on ...

Related keywords