STW5094 STMicroelectronics, STW5094 Datasheet - Page 23

no-image

STW5094

Manufacturer Part Number
STW5094
Description
Audio DSPs 14-Bit Linear CODEC
Manufacturer
STMicroelectronics
Datasheet

Specifications of STW5094

Mounting Style
SMD/SMT
Package / Case
TFBGA-36
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STW5094
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
STW5094
Manufacturer:
ST
0
Part Number:
STW5094AD/LF
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
STW5094AD/LF
Manufacturer:
ST
0
Part Number:
STW5094ADT-DICE
Manufacturer:
ST
0
Part Number:
STW5094T
Manufacturer:
TOKIN
Quantity:
14
PCM Interface Timing
I
Note:
2
Symbol
Symbol
C Bus Control Port Timing
t
t
t
t
t
t
t
SU:STO
t
t
t
HD:STA
HD:DAT
SU:DAT
SU:STA
t
t
t
t
HMFR
DMDR
DMZR
HMDR
t
t
t
t
SFMR
t
f
t
HIGH
DMD
SDM
HMD
LOW
HMF
SFM
DMZ
DFD
SCL
BUF
t
t
R
F
A signal is valid if it is above VIH or below VIL and invalid if it is between VIL and VIH.For the purpose of this specification the
following conditions apply (see Fig. 8):
a) All input signal are defined as: VIL = 0.2VCCIO, VIH = 0.8VCCIO, tR < 10ns, tF < 10ns.
b) Delay times are measured from the inputs signal valid to the output signal valid.
c) Setup times are measured from the data input valid to the clock input invalid.
d) Hold times are measured from the clock signal valid to the data input invalid.
Hold Time MCLK low to FS low
Setup Time, FS high to MCLK low
Delay Time, MCLK high to data
valid
Delay Time, MCLK low to
DX disabled
Delay Time, FS high to data valid
Setup Time, DR valid to MCLK
receive edge
Hold Time, MCLK low to DR
invalid
Hold Time MCLK High to FS low
Setup Time, FS high to MCLK
High
Delay Time, MCLK low to data
valid
Delay Time, MCLK High to DX
disabled
Hold Time, MCLK High to DR
invalid
Clock Frequency
Clock High Time
Clock Low Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Start Condition Hold Time
Start Condition Setup Time
Data Input Hold Time
Data Input Setup Time
Stop Condition Setup Time
Bus Free Time
Parameter
Parameter
Load = 20pF
Load = 20pF; Applies only if FS
rises later than MCLK rising edge
in Non Delayed Mode only
Load = 20pF
Test Condition
Test Condition
1300
1300
Min.
Min.
600
600
600
250
600
10
30
10
20
10
30
30
10
20
0
Typ.
Typ.
Max.
Max.
1000
100
100
100
100
100
400
300
STw5094
Unit
Unit
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
23/37

Related parts for STW5094