S-35399A03-J8T2G Seiko Instruments, S-35399A03-J8T2G Datasheet - Page 32

Real Time Clock 2-wire Real Time Clock

S-35399A03-J8T2G

Manufacturer Part Number
S-35399A03-J8T2G
Description
Real Time Clock 2-wire Real Time Clock
Manufacturer
Seiko Instruments
Datasheet

Specifications of S-35399A03-J8T2G

Supply Voltage (max)
3 V
Supply Voltage (min)
1.3 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Serial
Supply Current
0.34 uA
Package / Case
SOP-8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
32
2-WIRE REAL-TIME CLOCK
S-35399A03
Serial Interface
The S-35399A03 receives various commands via I
follows.
1. Start condition
2. Stop condition
3. Data transmission and acknowledgment signal
SDA
SCL
Data transmission is performed for every 1-byte, after detecting a start condition. Transmit data while the SCL line is in
“L”, and be careful of spec of t
is in “H”, the data will be recognized as start/stop condition in spite of data transmission. Note that by this case, the
access will be interrupted.
A start condition is when the SDA line changes “H” to “L” when the SCL line is in “H”, so that the access starts.
A stop condition is when the SDA line changes “L” to “H” when the SCL line is in “H”, and the access stops, so that the
S-35399A03 gets standby.
During data transmission, every moment receiving 1-byte data, the devices which work for receiving data send an
acknowledgment signal back. For example, as seen in Figure 34 , in case that the S-35399A03 is the device working for
receiving data and the master device is the one working for sending data; when the 8-bit clock pulse falls, the master
device releases the SDA line. After that, the S-35399A03 sends an acknowledgment signal back, and set the SDA line
to “L” at the 9-bit clock pulse. The S-35399A03 does not output an acknowledgment signal is that the access is not
being done regularly.
S-35399A03)
S-35399A03)
master device)
(Output from
(Input from
(Output from
SDA
SCL
SDA
t
SU.STA
Start condition
Start condition
t
HD.STA
Figure 34 Output Timing of Acknowledgment Signal
SU.DAT
t
SU.DAT
and t
Figure 33 Start/Stop Conditions
HD. DAT
1
Seiko Instruments Inc.
2
t
when changing the SDA line. If the SDA line changes while the SCL line
HD.DAT
C-bus serial interface to Read/Write data. Regarding transmission is as
High-Z
8
t
PD
t
SU.STO
Output acknowledgment
Stop condition
SDA is released
High-Z
(“L” active)
9
Rev.2.0
_00