M48T59Y-70MH1 STMicroelectronics, M48T59Y-70MH1 Datasheet - Page 22

Real Time Clock U 511-M48T59Y-70MH1E

M48T59Y-70MH1

Manufacturer Part Number
M48T59Y-70MH1
Description
Real Time Clock U 511-M48T59Y-70MH1E
Manufacturer
STMicroelectronics
Datasheet

Specifications of M48T59Y-70MH1

Function
Clock, Calendar, NV Timekeeping RAM, Watchdog Timer, Battery Backup, Alarm
Rtc Memory Size
8192 B
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Rtc Bus Interface
Parallel
Package / Case
SOIC-28
Time Format
HH:MM:SS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M48T59Y-70MH1
Manufacturer:
ST
Quantity:
5 510
Part Number:
M48T59Y-70MH1
Quantity:
5 510
Part Number:
M48T59Y-70MH1
Manufacturer:
ST
0
Part Number:
M48T59Y-70MH1
Manufacturer:
ST
Quantity:
20 000
Part Number:
M48T59Y-70MH1E
Manufacturer:
ST
0
Part Number:
M48T59Y-70MH1F
Manufacturer:
ST
0
5
Note:
Note:
22/32
DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the Measurement Conditions listed in
Designers should check that the operating conditions in their projects match the
measurement conditions when using the quoted parameters.
Table 9.
Output Hi-Z is defined as the point where data is no longer driven.
Figure 13. AC measurement load circuit
1. 50pF for M48T59V.
Excluding open-drain output pins
Table 10.
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
3. Outputs deselected.
Supply voltage (V
Ambient operating temperature (T
Load capacitance (C
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
Symbol
C
C
IO
IN
(3)
Input capacitance
Input / output capacitance
Operating and AC measurement conditions
Capacitance
CC
Parameter
)
L
)
C L includes JIG capacitance
Parameters
DEVICE
UNDER
TEST
A
)
(1)(2)
C L = 100pF
4.75 to 5.5
M48T59
0 to 70
0 to 3
645
100
1.5
5
(1)
M48T59Y
4.5 to 5.5
0 to 70
Min
0 to 3
100
1.5
AI02325
1.75V
5
Max
M48T59V
3.0 to 3.6
10
10
0 to 70
0 to 3
1.5
50
5
Table
Unit
pF
pF
Unit
pF
°C
ns
V
V
V
9.

Related parts for M48T59Y-70MH1