DS21455 Maxim Integrated Products, DS21455 Datasheet - Page 123
![no-image](/images/manufacturer_photos/0/4/417/maxim_integrated_products_sml.jpg)
DS21455
Manufacturer Part Number
DS21455
Description
Network Controller & Processor ICs Quad E1-T1-J1 Single -Chip Transceiver (S
Manufacturer
Maxim Integrated Products
Specifications of DS21455
Product
Framer
Number Of Transceivers
4
Data Rate
64 Kbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
328 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Package / Case
BGA
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS21455
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
DS21455+
Manufacturer:
Maxim Integrated Products
Quantity:
135
Company:
Part Number:
DS21455N+
Manufacturer:
Maxim Integrated Products
Quantity:
135
DS21455/DS21458 Quad T1/E1/J1 Transceivers
22. T1 BIT ORIENTED CODE (BOC) CONTROLLER
The DS21455/DS21458 contain a BOC generator on the transmit side and a BOC detector on the receive
side. The BOC function is available only in T1 mode.
22.1 Transmit BOC
Bits 0 through 5 in the TFDL register contain the BOC message to be transmitted. Setting BOCC.0 = 1
causes the transmit BOC controller to immediately begin inserting the BOC sequence into the FDL bit
position. The transmit BOC controller automatically provides the abort sequence. BOC messages will be
transmitted as long as BOCC.0 is set.
To transmit a BOC, use the following:
1) Write 6-bit code into the TFDL register.
Set SBOC bit in BOCC register = 1
2)
.
22.2 Receive BOC
The receive BOC function is enabled by setting BOCC.4 = 1. The RFDL register will now operate as the
receive BOC message and information register. The lower six bits of the RFDL register (BOC message
bits) are preset to all ones. When the BOC bits change state, the BOC change of state indicator, SR8.0
will alert the host. The host will then read the RFDL register to get the BOC message. A change of state
will occur when either a new BOC code has been present for time determined by the receive BOC filter
bits, RBF0 and RBF1, in the BOCC register.
To receive a BOC, use the following:
1) Set integration time via BOCC.1 and BOCC.2.
2) Enable the receive BOC function (BOCC.4 = 1).
3) Enable interrupt (IMR8.0 = 1).
4) Wait for interrupt to occur.
5) Read the RFDL register.
6) The lower six bits of the RFDL register is the message.
123 of 270