12211 Simpson, 12211 Datasheet

no-image

12211

Manufacturer Part Number
12211
Description
MULTIMETER, ANALOG, 7 FUNCTIONS
Manufacturer
Simpson
Datasheet

Specifications of 12211

Voltage Measuring Range Dc
250mV To 1000V
Voltage Measuring Range Ac
2.5V To 1000V
Current Measuring Range Dc
50µA To 5A
Current Measuring Range Ac
250A
Range Selection
Manual
Accuracy
+/- 2 %
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Simpson 260-6XLPM
Volt-Ohm-Milliammeter
INSTRUCTION MANUAL

12211 Summary of contents

Page 1

... Simpson 260-6XLPM Volt-Ohm-Milliammeter INSTRUCTION MANUAL ...

Page 2

... This warranty shall not apply to any instrument or other article of equipment which shall have been repaired or altered outside the SIMPSON ELECTRIC COMPANY factory or authorized service centers, nor which has been subject to misuse, neg- ligence or accident, incorrect wiring by others, or installation or use not in accord with instructions furnished by the manufacturer ...

Page 3

NOTES: 3 ...

Page 4

INTRODUCTION .............................................................................. 7 1.1 General Description ........................................................................... 7 1.2 Overload Protection ........................................................................... 7 1.3 Overload Circuit Reset ....................................................................... 7 1.4 Accessories and Supplies .................................................................. 8 1.5 Technical Data .................................................................................... 8 1.6 Test Leads ........................................................................................ 10 1.7 Safety Considerations ...................................................................... ...

Page 5

NOTES: 5 ...

Page 6

NOTES: 6 ...

Page 7

... The features, in combination with extended range coverage (Table 1-1) make this Instrument a general purpose, portable or laboratory Instrument well suited to servicing, production, inspection and engineering applications. The 260 uses the Simpson taut-band movement, which is self-shielding. The taut- band suspension provides a high degree of repeatability and is highly resistant to shock or vibration. ...

Page 8

... Table 1-2. 1.5 Technical Data Table 1-1 lists the technical specifications for the Simpson 260-6XLPM Volt-Ohm- Milliammeter. NOTE: Accuracy specifications apply to measurements made with the Instrument in a horizontal position (meter facing upward). Reference Conditions: +25°C ±5°C; ...

Page 9

DC CURRENT µ ...

Page 10

Table 1-2. Items and Accessories Supplied with the Instrument Quantity Description 1 Test Lead Set. One red and one black, 4 ft. long, with probe tip and removable rubber-sleeved alligator clip at one end and banana plug on opposite end. ...

Page 11

... A pair of test leads, one black and one red, are also included. 2.2 Warranty The Simpson Electric Company warranty policy is located on the inside front cover of this manual. Read it carefully before requesting a warranty repair. For all assis- tance, including help with the Instrument under warranty, contact the nearest Au- thorized Service Center for instructions ...

Page 12

... It is recommended that the Instrument be returned annually to your nearest Simpson Authorized Service Center the factory, for an overall check, adjustment and calibration. f. When not in use, store the Instrument in a room free from temperature ex- tremes, dust, corrosive fumes and mechanical vibration or shock ...

Page 13

Table 3-1. Controls and Connectors 1. Range Switch: The range switch has 18 positions. It may be turned to any position from either direction. There are seven voltage po- sitions, four direct current, six resistance and an OFF/TRAN- SIT position. ...

Page 14

Safety Precautions The 260 is intended for use only by personnel qualified to recognize shock haz- ards and trained in the safety precautions required to avoid possible injury not work alone when making measurements of circuits where ...

Page 15

Use a small screw- driver to turn the screw slowly clockwise or counterclockwise until the pointer rests freely over the zero mark at the left end of the ...

Page 16

... Measuring AC Voltage NOTE: The Simpson 260-6XLPM responds to the full wave average value waveform calibrated in terms of the RMS value of a pure sine wave. If the waveform is nonsinusoidal, the reading might be either higher or lower than the true RMS value and could result in a substantial error. Also, accuracy is lessened at higher input frequencies (Figure 4-1) ...

Page 17

AC VOLTAGE RANGES +5 2.5 VAC RANGE 10VAC RANGE +4 25 VAC RANGE 100 VAC RANGE +3 250 VAC RANGE + 100 HZ Figure 4-1. Typical Frequency Response, ACV Ranges a. ...

Page 18

Be sure the power is off in the circuit being measured and that all its capaci- tors have been discharged. Connect the test leads to the circuit with the black lead on the ground side. e. Turn on the ...

Page 19

Measuring Decibels To read voltages in terms of decibels, use the decibel (dB) scale on the bottom of the dial marked from -20 to +10. Read the dB scale by first following the instruc- tions for measuring AC. When ...

Page 20

Read the current the black DC scale marked 0-50 for the 0.5 mA ranges, divide the reading by 100 and 10, respectively. Read the 50 mA range directly. Multiply the reading on the 500 mA range ...

Page 21

NOTE: When the Instrument is not in use, do not leave the range switch in the low power ohms position because power is drawn continuously from the 1.5V battery. 4.11.2 Measuring Resistance: Conventional Ohm Ranges a. Turn the range switch ...

Page 22

... Do not use any instrument or test leads that are damaged contaminated deteriorated moist or have missing parts 4. Voltages as low as 30 volts rms volts peak can redner an electric shock 5. Read the Operator's Manual for additional precautions and instructions. SIMPSON ELECTRIC COMPANY ELGIN, ILLINOIS Figure 5-1. Battery and Fuse Compartment BATTERIES ...

Page 23

23 ...

Page 24

... SIMPSON ELECTRIC COMPANY 853 Dundee Avenue Elgin, IL 60120-3090 (847) 697-2260 FAX (847) 697-2272 Printed in U.S.A. Part No. 06-110940 Edition 16, 11/01 Visit us on the web at: www.simpsonelectric.com 24 ...