Specifications of U1271A

Dmm Type
Handheld
Voltage Measuring Range Dc
300mV To 1000V
Voltage Measuring Range Ac
300mV To 1000V
Current Measuring Range Dc
300µA To 10A
Current Measuring Range Ac
300µA To 10A
Lead Free Status / RoHS Status
na
AC specifications for U1272A
1. Notes for voltage specifications
2. Notes for current specifications
AC Current
True RMS AC
True RMS
Function
Voltage
Function
[2]
Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with <0.3 A current.
Input impedance: 10 MΩ (nominal) in parallel with <100 pF.
Z
The input signal is lower than the product of 20,000,000 V×Hz.
For 20 to 100 kHz accuracy: Three counts of the LSD per kHz of additional error is to be added for frequencies >20 kHz and signal inputs <10%
of range.
Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse
Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse
Specification for 300 mA range: 440 mA continuous.
Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals >10 to 20 A for 30 seconds
maximum. After measuring currents >10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
LOW
impedance: 2 kΩ (nominal)
[1]
3000 µA
300 mA
Range
300 µA
30 mA
10 A
Range
300 mV
1000 V
enabled, applicable for
3A
30 mV
all voltage ranges and
300 V
30 V
LPF (low pass fi lter)
3 V
Z
resolution
LOW
1000 V
Resolution
Resolution
0.001 mV
0.0001 V
0.01 mV
0.001 mA
0.001 V
0.0001 A
0.01 mA
0.01 µA
0.001 A
0.01 V
0.1 µA
0.1 V
0.6 + 20
0.6 + 20
0.6 + 20
0.6 + 20
0.6 + 20
0.6 + 20
0.6 + 20
2.0 + 40
65 Hz
Accuracy ± (% of reading + counts of least significant digit)
45 to
counts of least significant digit)
45 to 65 Hz
Accuracy ± (% of reading +
0.6 + 25
0.6 + 25
0.6 + 25
0.6 + 25
0.8 + 25
0.8 + 25
20 Hz to 1
1.0 + 25 @
5.0 + 25 @
10
2 + 40 @
<200 Hz
<440 Hz
<440 Hz
0.7 + 25
0.7 + 25
1.0 + 25
1.0 + 25
1.0 + 25
1.0 + 25
kHz
20 Hz to 2 kHz
0.9 + 25
0.9 + 25
0.9 + 25
0.9 + 25
1.0 + 25
1.0 + 25
1 kHz to 5
1.0 + 25
1.0 + 25
1.5 + 25
1.5 + 25
1.5 + 25
1.5 + 25
kHz
-
-
5 kHz to 20
Burden voltage/ Shunt
1.0 + 40
1.0 + 40
2.0 + 40
2.0 + 40
2.0 + 40
kHz
-
-
-
<0.04 V/ 100 Ω
<0.1 V/ 0.01 Ω
<0.3 V/ 0.01 Ω
<0.4 V/ 100 Ω
<0.08 V/ 1 Ω
<1.00 V/ 1 Ω
20 kHz to
100 kHz
3.5 + 40
3.5 + 40
3.5 + 40
3.5 + 40
-
-
-
-