Z218G GOSSEN METRAWATT, Z218G Datasheet

POWER PACK

Z218G

Manufacturer Part Number
Z218G
Description
POWER PACK
Manufacturer
GOSSEN METRAWATT
Datasheets

Specifications of Z218G

Dmm Type
Handheld
Voltage Measuring Range Dc
100mV, 1V, 10V, 100V, 1000V
Voltage Measuring Range Ac
100mV, 1V, 10V, 100V, 1000V
Dmm Response Type
True RMS
Ac Voltage Range Accuracy
90V - 250V
Approval Category
CAT
No. Of Digits / Alpha
4.5
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
METRAHIT⏐X-
TRMS Digital Multimeters
METRAHIT⏐B
METRAHIT⏐X-
Applications
The multimeter is suitable for universal use in electrical
engineering, electrical installation, laboratory applications,
telecommunication, training etc.
The instrument can be used in the field and is equipped with
internal, mains-independent supply power.
Features
Three Connector Jacks with Automatic Blocking Sockets (ABS) *
All current ranges are implemented via a single connector jack
which prevents any possibility of operator error.
Beyond this, the automatic blocking sockets prevent incorrect
connection of the measurement cables, as well as selection of the
wrong measured quantity. Danger to the user, the instrument and
the device under test resulting from operator error is thus ruled
out.
* Patented (patent no. DE 40 27 801 C2 and US 5,166,599)
Overload Protection
The instrument is safeguarded for up to 1000 V in all measuring
functions by overload protection. Voltages of greater than 1000 V
and current of greater than 10 or 16 A are indicated acoustically.
Dangerous contact voltages are indicated when the 1 kHz low-
pass filter is activated.
The FUSE display appears at
instruments in order to indicate that the fuse for the current mea-
suring input has blown.
GMC-I Gossen-Metrawatt GmbH
METRAHIT⏐X-
Digital Hand-Held Multimeter with RMS Measurement
V
4½-place display (11,999 digits), with display illumination
DKD calibration certificate
Current measurement via clip-on current sensor:
The transformation ratio is adjustable from 1 mV:1 mA to 1
mV:1 A, and is accounted for by the display.
Additional “low-resistance” (1 MΩ) alternating voltage measurement
1 kHz / -3 dB low-pass filter can be activated
Direct current measurement from 10 nA to 10 A, and 16 A for
short periods
Temperature measurement with Pt100(0) resistance thermometer
Broad range capacitance measurement
Frequency and keying ratio measurement at 2 to 5 V signals or up
to 1 MHz
Data memory and internal clock, power pack adapter socket
Bidirectional infrared interface for exchanging data with a PC
AC TRMS
, V
ASE
TRA
TRA
AC+DC TRMS
and
METRAHIT⏐P
, V
DC
TRA
METRAHIT⏐X-
, Hz (V), Hz (A), Ω, V
RO
⏐P
RO
TRA
and
⏐B
METRAHIT⏐P
ASE
, °C/°F (TC)
RO
RMS Value with Distorted Waveshape
The utilized measuring method allows for waveshape
independent RMS measurement (TRMS AC and AC+DC) for
voltage and current
Activatable Filter for V AC Measurement
A 1 kHz low-pass filter can be activated if required, for example
when measuring motor voltage at electronic frequency
converters. The input signal is checked by a voltage comparator
for dangerous voltages as long as the low-pass filter is activated.
Measuring 5 V Square-Wave Signals with the
This function makes it possible to test circuits and transmission
cables by measuring the frequency and the keying ratio of pulses
with amplitudes of 2 to 5 V and frequencies of 100 Hz to 1 MHz.
Analog Scale for Quick Trend Display – Bar Graph or Pointer
The analog scale (with additional negative range for zero-
frequency quantities) allows for faster recognition of measured
value fluctuation than is possible with a digital display.
The instrument can be switched back and forth between bar
graph and pointer display.
Automatic or Manual Measuring Range Selection
Measured quantities are selected by means of a rotary switch and
a function key. The measuring range is automatically matched to
the measured values. The measuring range can also be selected
and fixed manually with a key.
QUALITY MANAGEMENT SYSTEM
DIN EN ISO 9001:2000
DQS Certified per
reg. no.1262
(METRAHIT⏐X-
TRA
up to 20 kHz).
METRAHIT⏐X-
3-349-350-03
TRA
2/3.06

Z218G Summary of contents

Page 1

... METRAHIT⏐X- TRA TRMS Digital Multimeters • Digital Hand-Held Multimeter with RMS Measurement , Hz (V), Hz (A), Ω TRMS AC+DC TRMS DC • 4½-place display (11,999 digits), with display illumination • DKD calibration certificate METRAHIT⏐B ASE • Current measurement via clip-on current sensor: The transformation ratio is adjustable from 1 mV mV:1 A, and is accounted for by the display ...

Page 2

... The multimeters are furnished with an internationally valid DKD calibration certificate (recognized by EA and ILAC). After the specified calibration interval has elapsed (recommended interval years), the multimeters can be inexpensively recalibrated in our own DKD calibration laboratory. Applicable Regulations and Standards IEC/EN 61010, part ...

Page 3

... Hz 0.1 R ... 100 kHz 1 Hz 0.1 R Key measuring range, d= digit(s), rdg. = measured value (reading for U > 100 V ⏐P TRA TRMS Digital Multimeters Intrinsic Error under Reference Conditions ±(... % rdg. + ... d) ±(... % rdg. + ... d) ~ 10) 10 (> 300 (> 300 d) 0 (> 200 (> 300 d) 0 (> 200 (> ...

Page 4

... METRAHIT⏐X- TRA TRMS Digital Multimeters Internal Clock Time format DD.MM.YYYY hh:mm:ss Resolution 0.1 s ±1 min. per month Accuracy Temperature Influence 50 ppm/K Influencing Quantities and Influence Error Influencing Sphere of Measured Quantity / Quantity Influence Measuring Range V V 100 Ω ... 1 MΩ ...

Page 5

... Housing Dimensions Weight Protection Table excerpt regarding significance of the IP code digit ⏐P TRA TRMS Digital Multimeters METRAHIT⏐X- /METRAHIT⏐P TRA FF (UR) 10 A/1000 V AC/DC mm, Switching capacity 1000 V AC/ DC, protects the current measurement input in the 100 μA through 10 A ranges II III IV 1000 V ...

Page 6

... PC software is a multilingual, measurement data IEW logging program for recording, visualizing, evaluating and documenting measured values from METRAHIT⏐ multimeters. Communications between the PC and the measuring instrument(s) is established via the bidirectional IR-USB interface adapter. Depending upon device type, one or several of the following ...

Page 7

... RO Ever-ready case for 2 METRAHIT⏐, 2 adapters and accessories Z109L Hard case for one METRAHIT⏐ and accessories Z218G Hard case for two METRAHIT⏐ and accessories Z104C For additional information regarding accessories please refer to our Measuring Instruments and Testers catalog. ⏐P ...

Page 8

... WZ11A AC clip-on current transformer 1 ... 200 A~ Z3511 AC clip-on current transformer 4 ... 500 A~ Z3512 AC clip-on current transformer 0.5 ... 1000 A~ Z3514 AC clip-on current transformer 1 ... 2000 A ~ Shunt Resistors for Multimeters without Current Measuring Function NW300mA Plug-in shunt resistor, 0 ... 300 mA encapsulated NW3A Plug-in shunt resistor, 0 ... 3 A encapsulated ● ...