P01196787 CHAUVIN ARNOUX, P01196787 Datasheet - Page 5

no-image

P01196787

Manufacturer Part Number
P01196787
Description
MULTIMETER, DIGITAL, TRUE RMS AC CA5287
Manufacturer
CHAUVIN ARNOUX
Datasheet

Specifications of P01196787

Dmm Type
Handheld
Voltage Measuring Range Dc
50mV-1000V
Voltage Measuring Range Ac
50mV-1000V
Current Range Dc
500 µA - 10A
Current Range Ac
500 µA - 10A
Resistance Measuring Range
500
Frequency Measuring Range
99.999Hz To 999.99kHz
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
Signals for voltage
Sensitivity according to frequency and trigger level
The accuracy for the duty cycle and pulse width is based on one 5 V square-signal input on the 5 V
For AC coupling, the duty cycle range can be measured at 5 % ~ 95 % of the full range if the frequency of the signal is > 20 Hz.
Signals for current
Maximum input: please refer to AC current measurement.
n
Division of signal by 1 (secondary display “- 1 –”)
Division of signal by 100 (secondary display “-100 –”)
Duty cycle
Pulse width
n
• Output impedance: 3.5 kΩ maximum
50,000-count TRMS AC+DC multimeter
(16) The positive or negative pulse width must be greater than 50 µs for adjustment of the duty cycle or the pulse width at a different frequency. Otherwise, the accuracy and the range will be different
from the definition.
(17) For a signal frequency greater than 1 kHz, an extra 0.1 % per kHz must be added to the accuracy.
Frequency meter
Square-signal generator
Pulse width
accuracy = 10 x range or 1,000 V)
Duty cycle
9.9999 MHz
99.999 MHz
9.9999 MHz
9.9999 kHz
99.999 kHz
999.99 kHz
(Maximum input for specified
99.999 Hz
999.99 Hz
Frequency
0.01 %~99.99 %
Amplitude
Range
Range
Output
Input range
2,000 ms
Input range
Range
500 ms
5,000 µA
Range
1,000 mV
500 mA
500 µA
50 mA
500 mV
1,000 V
50 mV
10 A
500 V
5 A
50 V
(16)
5 V
(16)
0.5 - 1 - 2 - 5 - 10 - 15 - 20 - 25 - 30 - 40 - 50 - 60 - 75 - 80 - 100 - 120 - 150
- 200 - 240 - 300 - 400 - 480 - 600 - 800 - 1,200 - 1,600 - 2,400 - 4.800 Hz
0.0001 MHz
0.0001 MHz
Resolution
Resolution
0.0001 kHz
0.001 MHz
0.001 kHz
0.001 Hz
0.01 kHz
0.01 Hz
Accuracy of full scale
0.3 % per kHz + 0.3 %
Resolution
20 Hz-200 kHz
30 V < 100 kHz
50 V <100 kHz
0.01 ms
0.1 ms
Minimum sensitivity
Minimum sensitivity
120 mV
10 mV
70 mV
0.3 V
0.002 % + 5
0.002 % + 5
3 V
Accuracy
< 20 MHz
Accuracy
< 2 MHz
0.39 % ~ 99,60 %
Fixed 0~+ 2.8 V
1 / Frequency
Range
20 Hz-20 kHz
100 µA
250 µA
10 mA
25 mA
2.5 A
1 A
300 mVrms
500 mVrms
(RMS value – sine wave)
Sensitivity
100 mVrms
200 mVrms
(RMS value – sine wave)
Sensitivity
> 200 kHz ~ 500 kHz
Accuracy
0.2 % + 3
0.2 % + 3
No spec.
No spec.
dc
150 mV
300 mV
25 mV
0.5 V
DC coupling
range.
5 V
Mode
Min. input freq.
Min. input freq.
1 MHz
0.5 Hz
The maximum measurement level is < 30 Vp-p (peak-peak voltage).
To optimize the number of measurements per second for low
frequencies, the minimum measurement frequency must be set in
the SET-UP menu.
All frequency meters are liable to give erroneous measurements
when measuring low-voltage, low-frequency signals. It is essential
to shield the inputs against external noise in order to reduce
measurement errors to a minimum.
The accuracy for the duty cycle and the pulse width is based on a
5 V square-wave signal without signal division.
The accuracy for the duty cycle and the pulse width is based on a
5 V square-wave signal without signal division.
The positive or negative pulse width must be greater than 10 µs and
the duty cycle should be taken into account. The pulse width scale is
determined by the signal’s frequency.
0.390625 %
Range / 256
Resolution
< 100 kHz
0.01 Hz
0.1 V
120 mV
10 mV
70 mV
120 V
0.6 V
60 V
6 V
Trigger level for DC coupling
0.4% of full scale
0.2 ms + range / 256
C.A 5289
> 100 kHz ~ 500 kHz
0.005 % + 2
Accuracy
0.2 V
No spec.
No spec.
150 mV
300 mV
25 mV
1.5 V
15 V
(17)