P01196789 CHAUVIN ARNOUX, P01196789 Datasheet - Page 3

no-image

P01196789

Manufacturer Part Number
P01196789
Description
MULTIMETER DIGITAL TRMS AC+DC CA5289
Manufacturer
CHAUVIN ARNOUX
Datasheet

Specifications of P01196789

Dmm Type
Handheld
Voltage Measuring Range Dc
50mV-1000V
Voltage Measuring Range Ac
50mV-1000V
Current Range Dc
500 µA - 10A
Current Range Ac
500 µA - 10A
Resistance Measuring Range
500 Ohm -
Frequency Measuring Range
99.999Hz To 9.9999MHz
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
n
- Input impedance:
• for the ranges from 50 mV to 1,000 mV: > 1 GΩ
• for the ranges from 5 V to 1,000 V: 1.1 MΩ (nominal) in parallel with < 100 pF (nominal)
- Crest factor: ≤ 3
n
n
n
- Crest factor ≤ 3
n
- Crest factor ≤ 3
50,000-count TRMS AC+DC multimeter
(1) Protection 1,000 Vrms for Ip-p < 0.3 A
(5) For input voltages lower than 200 Vrms, add 125 counts: 3.5 % + 125
(6) For input voltages lower than 200 Vrms, add 45 counts: 1.5 % + 45
(7) Always use the “Relative” function to offset the thermal effect with the measurement leads open before
measuring the signal. If the “Relative” function is not used, you must add 20 counts to the accuracy. The thermal
effect could occur in the following cases:
- Overheating due to manipulation error by a applying a high voltage of 50 V to 1,000 V for resistance
- Overheating after battery recharging.
- Overheating after measuring a current higher than 500 mA: it is recommended to leave the multimeter to cool
measurement, diode test and mV functions.
for twice the time that the current is applied.
AC+DC Voltage (root mean square value: 5 % to 100 % of the range)
dB (calculation of decibels)
DC Current
AC Current (root mean square: 5 % to 100 % of the range)
AC+DC Current (root mean square value: 5 % to 100 % of the range)
1 mW (dBm)
1 V (dBV)
500 µA
500 µA
1,000 mV
dB base
5 000 µA
5 000 µA
5,000 µA
500 mV
500 mA
500 mA
500 mA
50 mV
500 µA
Range
10 A
10 A
Range
10 A
50 mA
Range
50 mA
50 mA
1,000 V
Range
500 V
5 A
5 A
5 A
50 V
5 V
(8)
(8)
(8)
(10)
(10)
(1)
(1)
(1)
1 to 9.999 Ω
Reference
Resolution
Resolution
0.001 mA
0.001 mA
0.0001 A
0.0001 A
1 V
0.01 mA
0.01 mA
0.01 µA
0.001 A
Resolution
0.01 µA
0.001 A
0.1 µA
0.1 µA
Resolution
0.001 mA
0.0001 A
0.01 mA
0.01 µA
0.001 A
0.001 mV
0.0001 V
0.01 mV
0.1 µA
0.001 V
0.1 mV
0.01 V
0.1 V
reference
Default
600 Ω
1 V
1.5 % + 50
1.5 % + 40
1.5 % + 40
1.5 % + 40
20~45 Hz
2.2 % + 50
1.6 % + 55
1.6 % + 45
1.7 % + 45
1.7 % + 45
2 %
2 %
30~45 Hz
2.2 %
1.2 % + 80
1.2 % + 65
1.2 % + 65
1.2 % + 65
1.2 % + 65
1.2 % + 65
1.2 % + 65
30~45 Hz
0.05 % + 5
0.05 % + 5
0.15 % + 5
0.15 % + 5
(9)
(9)
0.2 % + 10
Accuracy
0.2 % + 5
(12)
(11)
General remarks:
The power decibels display uses the reference 1 mW whereas the voltage decibels display uses the reference 1 V.
Although the formula shows that the accuracy of the result depends on the accuracy of the voltage measurement, an
additional error of 0.3 dB should be added due to the calculation.
Autoranging is used for measurements in decibels. The bandwidth depends on the voltage measurement.
(7)
(7)
(7)
(7)
0.7 % + 20
0.7 % + 20
0.7 % + 20
0.7 % + 20
0.7 % + 20
0.7 % + 20
45~2 kHz
0.8 % + 25
0.8 % + 25
0,9 % + 25
0,9 % + 25
0,9 % + 30
0,9 % + 25
Accuracy
45~2 kHz
0.4 % + 60
0.4 % + 30
0.4 % + 30
0.4 % + 30
0.4 % + 30
0.4 % + 30
0.4 % + 45
Accuracy
45~1 kHz
Load voltage / Shunt
0.21 V (0.01 Ω)
0.05 V (100 Ω)
< 3 A / 5 kHz
0.1 V (0.01 Ω)
0.5 V (100 Ω)
2 k~20 kHz
0.08 V (1 Ω)
0.8 V (1 Ω)
3 % + 80
3 % + 60
3 % + 60
3 % + 60
3 % + 60
< 3 A / 5 kHz
2 k~20 kHz
3.1 % + 85
3.1 % + 65
3.2 % + 65
3.2 % + 65
3.2 % + 70
(8) An additional 0.5% error should be applied to the accuracy of the 10 A
calibre when measuring currents between 10 A and 20 A for a maximum of 30
seconds. After a current measurement > 10 A, and before carrying out any low-
current measurements, leave the multimeter to cool for twice the time that the
current was applied.
(9) For currents < 3 Arms, ad an uncertainty of 40 counts (2 % + 40)
(10) Minimum intensity measured Imin > 35 µArms
(11) For currents lower than 3 Arms, add 50 counts: 2.2 %+ 50
(12) For currents lower than 3 Arms, add 45 counts: 2.2 % + 45
1 k~10 kHz
0.7 % + 60
0.4 % + 30
0.4 % + 30
0.4 % + 30
0.4 % + 30
0.4 % + 30
0.4 % + 45
Accuracy
20 k~100 kHz
5 % + 80
5 % + 80
5 % + 80
5 % + 80
No spec.
No spec.
Protection against overloads
10 k~20 kHz
1.5 % + 60
1.5 % + 45
1.5 % + 45
1.5 % + 45
1.5 % + 45
1.5 % + 45
Protection against overloads
11 A HRC fuse - 10 x 38 mm
1.5 %
Protection against overloads
440 mA HRC fuse
11 A HRC fuse, 10 x 38 mm
1,000 V / 30 kA
1,000 V / 30 kA
11 A HRC fuse
440 mA HRC fuse
10 x 38 mm
10 x 38 mm
1,000 V / 30 kA
1,000 V / 30 kA
(6)
10 x 38 mm
440 mA HRC fuse
1 000 V / 30 kA
1,000 V / 30 kA
C.A 5289
10 x 38 mm
20 k~100 kHz
3.5 % + 220
3.5 % + 125
3.5 % + 125
3.5 % + 125
3.5 % + 125
No spec.
3.5%
(5)
3