DIGITAL MULTIMETER
5
RMS
True RMS
Capacitance
PC5000
• 0.03% Basic Accuracy
• AC / AC + DC True RMS
• 50000 & 500000 count
• Selectable 5 sensitivity for Hz
• 0.01 ohm resolution
• 0.01m V AC/DC resolution
• Line, Logic Frequency measurement
• Frequency 0.0001Hz resolution
• dBm 20 selectable reference impedance
• 4 - 20mA % measurement
• Capacitance 0.01nF up to 9.999mF
• Duty Cycle measurement
• Capture (peak hold) 0.8ms in duration
• MAX, MIN, MAX-MIN recording mode
• Data hold, Relative Value
• Auto power off (Enable or Disable)
• Fast response Cont. Buzzer
• Tilt stand
• Set off Beeper function
• Protective holster
Display: numeral display 50000 & 500000 selectable, Bargraph 52 segments
Sampling rate: 5 times / sec for 50000 count numeral display, 1.25 times / sec for 500000 count numeral display, 60 times / sec for Bargraph,
Bandwidth: V:45Hz~1kHz, 1kHz~20kHz(below 500V), A:40Hz~1kHz
Safety: IEC1010 CAT.III 600V Max / CAT.II 1000V Max
50000 count & 500000 count
selectable AC / AC + DC True RMS
PC520M
43,000 Points Data Logged
in built-in Memory
• AC True RMS
• 5000 count
• 0.08% Basic Accuracy
• Selectable 5 sensitivity for Hz
• 0.01 ohm resolution
• 0.01m V AC/DC resolution
• K-type temperature –50°C ~ 1000°C
• Capacitance 0.01nF up to 9.999mF
• Auto power off (Enable or Disable)
• Fast response Cont. Buzzer
• Fast speed bargraph (60times/sec.)
• Tilt stand
• Set off Beeper
• Protective holster
Data Logging mode
• 43,000 data points logged in built-in memory
• Call and Scrolling logged data in the LCD
• MAX MIN data logged can appear in the LCD
• Search of MAX & MIN data logged at turning
• Selection of measurement interval from 0.05s,
• Automatic Standby mode during data logging
• Automatic stopping data logging mode when
• Download data logged to PC
(DCV & Hz range) selectable
point
1s, 20s, 40s, 1min, 2min, 4min, 8min (From
0.2s for °C & ohm, 0.4s for Hz )
to extend Battery life
batteries are low to guarantee accuracy of
every logged data
Hz
Frequency
NEW
NEW
NEW
NEW
http://www.sanwa-meter.co.jp
℃
Temperature
REL
Relative
Optional accessories
Software: PCLink, PCLink Plus
Optical RS232 cable: KB-RS2
Temperature probe: T-300PC
Accuracy: ±(rdg.% + dgt.) 18∼25℃、75%RH max. No condensation
Accuracy: ±(rdg.% + dgt.) 18∼25℃、75%RH max. No condensation
Optional accessories
Software: PCLink, PCLink Plus
Optical RS232 cable: KB-RS2
K type adapter: K-AD
Function
Batt/Fuse
Size/Weight H179×W87×D55mm
Accessories
Display: numeral display 5000, Bargraph 52 segments
Sampling rate: 5 times / sec, 60 times / sec for Bargraph
Bandwidth: 40Hz~20kHz (below 500V), 40Hz-1kHz (ACA)
Safety: IEC1010 CAT.III 600V Max / CAT.II 1000V Max
Function
Batt/Fuse
Size/Weight H179×W87×D55mm
Accessories
DCV
ACV (AC+DC)
DCA
ACA (AC+DC)
Resistance
Capacitance
Frequency
Logic Frequency
Duty Cycle
dBm
%4∼20mA
Continuity
Diode Test
DCV
ACV
DCA
ACA
Resistance
Capacitance
Temperature
Frequency
Continuity
Diode Test
232C
RS
RS232
output
232C
RNG
HOLD
500m/5/50/500/1000V
500m/5/50/500/1000V
500μ/5m/50m/500m/5/10A
500μ/5m/50m/500m/5/10A
500/5k/50k/500k/5M/50MΩ
50n/500n/5μ/50μ/500μ/9999μF
5Hz∼200kHz
5Hz∼2MHz
0.1%∼99.99%
-11.76dBm∼54.25dBm at 600Ω
4mA=0%, 20mA=100%,
Buzzer sounds at between 20Ω and 200Ω. Open voltage: Approx. 3V
Open voltage: Approx. 3.5V
6LF22(9V) x 1
Test Lead (TL-82), Clip Lead (CL-13), Holster (H-50), Instruction Manual-
RS
50m/500m/5/50/500/1000V
50m/500m/5/50/500/1000V
500μ/5m/50m/500m/5/10A
500μ/5m/50m/500m/5/10A
50/500/5k/50k/500k/5M/50MΩ
50n/500n/5μ/50μ/500μ/9999μF
-50℃∼1000℃
5Hz∼125kHz
Buzzer sounds at between 20Ω and 120Ω. Open voltage: Approx. 3V
Open voltage: Approx. 3.5V
6LF22(9V) x 1
Test Lead (TL-82), Clip Lead (CL-13), K-type thermocouple
(K-250PC), Holster (H-50), Instruction Manual
Measuring Range
Measuring Range
RNG
HOLD
RMS
HOLD
DATA
Range
Hold
232C
RNG
HOLD
RS
Clamp prove: CL-20D, CL-22AD, CL33DC
Carrying case: C-CD
Temperature probe: K-8-250~800
Clamp prove: CL-20D, CL-22AD, CL33DC
Carrying case: C-CD
DATA
HOLD
RMS
HOLD
DATA
Hz
12.5A/500V IR 20kA φ6.3×32
Best Accuracy Resolution Input resistance
0.03%+2
0.8%+60
0.002%+4
0.002%+4
0.25dB+2
0.08%+2
0.5%+3
0.2%+4
0.6%+3
0.2%+2
0.8%+3
0.3%+3
0.01%+2
12.5A/500V IR 20kA φ6.3×32
0.63A/250V IR 1.5kA φ5.2×20
460g (including protective holster)
3d/kHz+2
0.63A/250V IR 1.5kA φ5.2×20
460g (including protective holster)
Best Accuracy Resolution
0.1%+2
1.0%+4
0.2%+6
0.8%+3
±d25
Data
Hold
OFF
REL
AP
Cal
TLR
10μV
10μV
0.01μA
0.01μA
10mΩ
0.01nF
0.0001Hz
0.0001Hz
0.01%
10μV
10μV
0.1μA
0.1μA
10mΩ
0.01nF
1℃
0.001Hz
Cal
TLR
Capture
Hz
Test Lead
Resistance
Calibration
Input resistance
10MΩ
10MΩ
MAX
Duty
OFF
MIN
℃
AP