Z109L GOSSEN METRAWATT, Z109L Datasheet - Page 2

FUSE, PK10

Z109L

Manufacturer Part Number
Z109L
Description
FUSE, PK10
Manufacturer
GOSSEN METRAWATT
Datasheets

Specifications of Z109L

Dmm Type
Handheld
Voltage Measuring Range Dc
100mV, 1V, 10V, 100V, 1000V
Voltage Measuring Range Ac
100mV, 1V, 10V, 100V, 1000V
Dmm Response Type
True RMS
Current Max
10A
Input Voltage Max
1kV
No. Of Digits /
RoHS Compliant
No. Of Digits / Alpha
4.5
Rohs Compliant
NA
METRAHIT⏐X-
TRMS Digital Multimeters
Fast Acoustic Continuity Test
Testing for short circuiting and interruption is possible with the
selector switch in the
acoustic signaling can be set to 1, 10, 20, 30, 40 or 90 Ω.
Automatic Storage of Measured Values *
The DATA function automatically saves the digitally displayed
measured value after settling in. Acoustic signaling is also used to
indicate whether the new measured value deviates from the initial
reference value by less or more than 0.1% of the measuring
range.
* Patented
Storage of Min-Max Values
Comparable to the slave-pointer function of an analog instrument,
the device saves the highest and lowest measured values after
the MIN/MAX function has been activated or reset. These
extreme values can be queried at the display.
Battery Charging Status – Power Saving Circuit
The battery charging status is indicated by means of four sym-
bols.
The device is switched off automatically if the measured value
remains unchanged for a period of between 10 and 59 minutes
(adjustable), and if none of the controls are activated during this
time.
Automatic shutdown can be deactivated by switching the
instrument to continuous operation.
METRAHIT⏐X-
standby mode.
Protective Cover for Harsh Conditions
The instrument is protected against damage in the event of
impacts or dropping by means of a soft rubber cover with tilt
stand and test probe holder. The rubber material also assures that
the instrument does not wander if it is set up on a vibrating
surface.
Infrared Data Interface with
The device can be remote configured, and momentary and stored
measurement data can be read out via the bidirectional infrared
interface. The
software are required to this end (see accessories). Interface
protocol and device driver software for LabVIEW
Instruments™) are available upon request.
DKD Calibration Certificate
The multimeters are furnished with an internationally valid DKD
calibration certificate (recognized by EA and ILAC). After the
specified calibration interval has elapsed (recommended interval:
1 to 3 years), the multimeters can be inexpensively recalibrated in
our own DKD calibration laboratory.
Applicable Regulations and Standards
2
IEC/EN 61010, part
1:2001/VDE 0411-1:2002
DIN EN 61326
VDE 0843, part 20
DIN EN 60529
DIN VDE 0470, part 1
TRA
USB⏐X-
: The infrared interface can be switched off in the
Safety requirements for electrical equipment for
measurement, control and laboratory use
Electrical equipment for control technology and laboratory use
– EMC requirements
Test instruments and test procedures
– degrees of protection provided by enclosures (IP code)
TRA
METRAHIT⏐X-
position. The threshold value for
interface adapter and
TRA
⏐P
TRA
RO
⏐B
METRA⏐V
®
(National
ASE
IEW
Selection List
1)
2)
Included
1 multimeter
1 pair of safety measurement cables (1.5 m) with 4 mm test
2 batteries, 1.5 V, type AA
1 condensed operating instructions, English/German
1 CD ROM (operating instructions in English and German),
1 DKD calibration certificate
1 protective rubber cover
Voluntary Manufacturer’s Guarantee
24 months for materials and workmanship
1 to 3 years for calibration (depending upon application)
Function
V AC / Hz
(Ri = 10 MΩ) TRMS
V AC (Ri = 1 MΩ)
TRMS
V AC+DC (Ri = 10 MΩ)
TRMS
V DC (Ri = 10 MΩ)
... 1 MHz 5 V AC
Keying ratio as %
Hz (V AC)
Bandwidth, V AC
A AC / Hz TRMS
A AC+DC TRMS
A DC
Fuses
A AC
A AC+DC
A DC
Hz (A AC)
Clip factor
Resistance
Continuity
Diode ... 5.1 V
Temperature TC (K)
Temperature RTD
Capacitance
Min-Max / data hold
4 MBit memory
IR Interface
Power pack adapter
socket
Protection
Measuring category
For 15,400 measured values, sampling rate adjustable from 0.1 second to 9 hours
IP 65 in preparation
probes, 1000 V CAT III, 600 V CAT IV (KS17-2)
METRA⏐V
/ Hz TRMS
1 )
Ri = 1 MΩ
Ω
TRMS
1)
IEW
1)
demo software in preparation
1)
METRAHIT⏐X-
15 Hz ... 20 kHz
1 A / 10 (16) A
10 A / 1000 V
1000 V CAT III
1kHz
1kHz
1/10/100 mA
600 V CAT IV
... 100 kHz
... 30 kHz
100 μA
IP 52
(METRAHIT⏐X-
Filter
Filter
2)
TRA
METRAHIT⏐P
GMC-I Gossen-Metrawatt GmbH
15 Hz ... 10 kHz
1 A / 10 (16) A
1000 V CAT III
10 A / 1000 V
1kHz
1kHz
600 V CAT IV
... 100 kHz
... 30 kHz
IP 52
TRA
Filter
Filter
2)
only)
RO
METRAHIT⏐B
15 Hz ... 1 kHz
1000 V CAT III
600 V CAT IV
... 100 kHz
... 30 kHz
IP 52
ASE