E4404B STG AGILENT TECHNOLOGIES, E4404B STG Datasheet - Page 10

ANALYZER, SPECTRUM, 9KHZ To 6.7GHZ

E4404B STG

Manufacturer Part Number
E4404B STG
Description
ANALYZER, SPECTRUM, 9KHZ To 6.7GHZ
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of E4404B STG

Spectrum Analyzer Type
Bench
Frequency Measuring Range
9kHz To 6.7GHz
Sensitivity Dbm
-139dBm
External Height
222mm
External Width
416mm
External Depth
409mm
Weight
37.7lb
Lead Free Status / RoHS Status
na
Amplitude Specifications
10
a.
b.
c.
d.
e.
Input attenuator switching uncertainty (at 50 MHz)
Frequency response (10 dB input attenuation)
At reference settings
Preamp on
Overall amplitude accuracy e
(95% confidence) f
Attenuator setting
Absolute amplitude accuracy
Display scale fidelity
Log max cumulative
Log incremental accuracy
Linear accuracy
dB below reference level
Absolute a /typical/relative b
> 98 to 120 dB
0 to 80 dB g
> 0 to 10 dB
> 10 to 20 dB
> 20 to 30 dB
> 30 to 40 dB
> 40 to 50 dB
> 50 to 60 dB
> 60 to 70 dB
> 70 to 80 dB
> 80 to 85 dB
RBW ≤ 300 Hz (Option 1DR)
span > 0 Hz, auto range on
0 to 98 dB g
0 dB to 5 dB
10 dB
15 dB
20 dB to 60 dB
100 Hz to 9 kHz c
9 kHz to 3 GHz
3 GHz to 6.7 GHz
6.7 GHz to 13.2 GHz
13.2 GHz to 26.5 GHz
Frequency response values are referenced to the amplitude at 50 MHz
(20 to 30 °C).
Referenced to midpoint between highest and lowest frequency response
deviations (20 to 30 °C).
Custom path ESA-E only Option UKB, typical.
Settings are: reference level -25 dBm; (75 Ω reference level +28.75 dBmV);
input attenuation 10 dB; center frequency 50 MHz; RBW 1 kHz; VBW 1 kHz;
amplitude scale linear or log; span 2 kHz; frequency scale linear; sweep time
coupled, sample detector, signal at reference level.
For reference level 0 to -50 dBm; input attenuation 10 dB; RBW 1 kHz;
VBW 1 kHz; amplitude scale log, log range 0 to -50 dB from reference level;
frequency scale linear; sweep time coupled; signal input 0 to -50 dBm;
span ≤ 20 kHz. (20 to 30 °C).
dB below reference level
RBW ≥ 1 kHz
0 dB reference
d
± (0.6dB + absolute frequency response)
± (0.3dB + 0.01 x dB
± 0.5 dB/NA/± 0.5 dB
± 1.5 dB/NA/± 1.3 dB
± 2 dB/NA/± 1.8 dB
from reference level
Basic analyzer
± 0.4 dB
N/A
N/A
N/A
N/A
± 2.0 dB from reference level, characteristic
f.
g.
± (0.1 dB + 0.01 x attenuator setting)
Input frequency < 3GHz; -50 dBm ≤ input power ≤ 0 dBm; -50 dBm ≤ reference
level ≤ 0 dBm; -20 dB ≤ input power - ref level ≤ 0 dB; input attenuation = 10 dB;
10 Hz ≤ RBW ≤ 1 MHz; (20 to 30 °C). Computed from the observation of a
statistically significant number of instruments. Observations of the 50 MHz
amplitude accuracy, a component of the computation of this number are
performed immediately after invoking RF and IF alignments to minimize the
effects of alignment drifts.
0 to 30 dB for RBW = 200 Hz.
± 2% of reference level
± (0.3dB + 0.01 x dB
from reference level)
± 0.4 dB / 4 dB
Reference
± 0.3 dB
Standard, communications test analyzer or
± (0.54 dB + absolute frequency response)
± 0.5 dB/NA/± 0.5 dB
± 0.46 dB/± 0.14 dB/± 0.5 dB
± 1.5 dB/± 0.38 dB/± 1.3 dB
± 0.34 dB, ± 0.13 dB typical
± 0.37 dB, ± 0.14 dB typical
± 0.5 dB/NA/± 0.5 dB
± 2 dB/± 0.68 dB/± 1.8 dB
± 2 dB/± 0.86 dB/± 1.8 dB
custom configuration
±1.15 dB, typ ±0.79 dB
±0.3 dB, typ ±0.08 dB
±0.4 dB, typ ±0.09 dB
±0.6 dB, typ ±0.23 dB
±0.7 dB, typ ±0.35 dB
±0.7 dB, typ ±0.35 dB
±0.8 dB, typ ±0.39 dB
±0.8 dB, typ ±0.46 dB
±0.5 dB, typ ±0.1 dB
± 0.4 dB (95%)
0 dB
a
(Option UKB)