U8202A AGILENT TECHNOLOGIES, U8202A Datasheet - Page 6

Test Leads U3400 U3606A U3401A U3402A

U8202A

Manufacturer Part Number
U8202A
Description
Test Leads U3400 U3606A U3401A U3402A
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U8202A

Voltage Rating
1000V
Kit Contents
Alligator Clips, Mini Grabber Sand Fine-tips Test Probes And Test Probe Leads
For Use With
U3400 Series, U3401A, U3402A, And U3606A
Lead Free Status / RoHS Status
na
Digital multimeter specifications (continued)
Frequency specifications
1. For 100 mV and 1 V ranges, the measurable frequency is up to 1 MHz at 0.5 V input signal.
2. Maximum input for the specified accuracy = 10 x range or 1000 V
All frequency counters are susceptible to errors when measuring low-voltage, low-frequency signals. Shielding inputs from
external noise pickup is critical for minimizing measurement errors.
Duty cycle and pulse width specifications
1. The range is from {10 µs × frequency × 100%} ~ {[1 – (10 µs × frequency)] × 100%}. For example, a 1 kHz signal can be measured from
2. The positive or negative pulse width must be greater than 10 µs. The range of the pulse width is determined by the frequency of the signal.
Function
Frequency
Input range
100 mV
1.0 V
10 V
100 V
750 V
Input range
10 mA
100 mA
1 A
3 A
Function
Duty cycle
Pulse width
1% ~ 99%.
2
Input range
Voltage:
100 mV to 750 V
Current:
10 mA to 3 A
Minimum frequency sensitivity for voltage measurement (RMS sine wave)
20 Hz to 100 kHz
50 mV
100 mV
1 V
10 V
100 V
Minimum frequency sensitivity for current measurement (RMS sine wave)
20 Hz to 100 kHz
1 mA
10 mA
100 mA
300 mA
Range
100.000%
199.999 ms
1999.99 ms
1
1
2
2
Frequency range:
minimum input
frequency = 1 Hz
< 2 Hz
< 20 Hz
20 Hz to 100 kHz
100 kHz to 300 kHz
< 2 Hz
< 20 Hz
20 Hz to 10 kHz
dc
Resolution
0.001%
0.001 ms
0.01 ms
.
100 kHz to 300 kHz
50 mV
120 mV
1.2 V
12 V
6
Accuracy
±(% of reading + % of range)
1 year (23 ºC ± 5 ºC)
0.18 + 0.003
0.04 + 0.003
0.02 + 0.003
0.02 + 0.003
0.18 + 0.003
0.04 + 0.003
0.02 + 0.003
Accuracy at full scale
0.3% + 0.2% per kHz
Duty cycle/frequency
Duty cycle/frequency
300 kHz to 1 MHz
0.5 V
0.5 V
Temperature
coefficient
0 ºC to 18 ºC
28 ºC to 55 ºC
0.005
0.005
0.005
0.005
0.005
0.005
0.005