I30 Fluke, I30 Datasheet - Page 3

no-image

I30

Manufacturer Part Number
I30
Description
Clamp Meters
Manufacturer
Fluke
Datasheet

Specifications of I30

Test Probe Type
Multi-Function
Test Probe Functions
Current
Accuracy
± 1%
Current Ac Max
20A
Current Measuring Range
± 30A
Current Measuring Range Dc
5mA To 30A
Dmm Response Type
Average
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
I3002L
Quantity:
133
Part Number:
I3002L-TP
Manufacturer:
INTERPION
Quantity:
20 000
Part Number:
I3010-13.000-9
Quantity:
470
Part Number:
I3010-13.000-9
Manufacturer:
ITTI
Quantity:
20 000
Fluke i30 AC/DC Current Clamp
Electrical specifications
Current range
Measuring range
Output sensitivity
Accuracy (at +25 °C)
Resolution
Load impedance
Conductor position
sensitivity
Frequency range
Temperature coefficient
Power supply
Working voltage (see
Safety Standards section)
General Specifications
Maximum conductor size
Output connection
Output zero
Cable length
Operating temperature
range
Storage temperature range
(with battery removed)
Operating humidity
Weight
Safety standards
EMC Standards
© 1995 - 2008 Fluke Corporation
20 A ac rms or dc
± 30 A
100 mV/A
± 1 % of reading ± 2 mA
± 1 mA
> 10 k Ohms and ≤ 100pF
± 1 % relative to center reading
DC to 20 kHz (- 0.5 dB)
± 0.01 % of reading/°C
9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
300 V ac rms or dc
19 mm diameter
4 mm safety connector
Manual adjust via thumbwheel
1.5 meters
0 °C to +50 °C
-20 °C to +85 °C
15 % to 85 % (non-condensing)
250 g
BS EN 61010-1:2001
BS EN 61010-2-032:2002
BS EN 61010-031:2002
300 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc
and frequencies below 1 kHz.
EN 61326: 1998 +A1, A2, & A3