I30S Fluke, I30S Datasheet

no-image

I30S

Manufacturer Part Number
I30S
Description
AC CURRENT PROBE
Manufacturer
Fluke
Datasheet

Specifications of I30S

Test Probe Type
Multi-Function
Test Probe Functions
Current
Accuracy
± 1%
For Use With
Oscilloscopes And Other Suitable Recording Instruments
Lead Free Status / RoHS Status
na
Products
Fluke i30s AC/DC Current Clamp
Electrical specifications
Current range
Measuring range
Output sensitivity
Accuracy (at +25 °C)
Resolution
Load impedance
Conductor position
sensitivity
Frequency range
Phase shift below 1 kHz
Temperature coefficient
Power supply
Working voltage (see
Safety Standards section)
General specifications
Maximum conductor size
Output connection
Output zero
Cable length
Operating temperature
range
Storage temperature range
(with battery removed)
Operating humidity
Weight
Safety standards
EMC Standards
© 1995 - 2008 Fluke Corporation
20 A ac rms or dc
± 30 A
100 mV/A
± 1 % of reading ± 2 mA
± 1 mA
> 100 kΩ
± 1 % relative to center reading
DC to 100 kHz (- 0.5 dB)
< 2 degrees
± 0.01 % of reading/°C
9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
300 V ac rms or dc
19 mm diameter
Safety BNC connector, supplied with safety 4 mm adapter
Manual adjust via thumbwheel
2 meters
0 °C to +50 °C
-20 °C to +85 °C
15 % to 85 % (non-condensing)
250 g
BS EN 61010-1: 2001
BS EN 61010-2-032: 2002
BS EN 61010-031: 2002
300 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 300 V acrms or dc
and frequencies below 1 kHz.
EN 61326: 1998 +A1, A2, & A3