N2790A AGILENT TECHNOLOGIES, N2790A Datasheet
![TEST PROBE, OSCILLOSCOPE](/photos/27/72/277213/4657098_sml.jpg)
N2790A
Specifications of N2790A
N2790A Summary of contents
Page 1
... Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth ground. Use the N2790A, N2791A or N2891A high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A, N2791A and N2891A high-voltage differential probes allow conventional earth-grounded Agilent oscilloscopes to be used for floating signal measurements ...
Page 2
... With a differential amplifier in the probe head, the N2790A is rated to measure differential voltage up to 1,400 VDC + peak AC with high CMRR (common mode rejection ratio) of > MHz. The N2791A and N2891A can measure differential voltage up to 700 V and 7 kV differential or common mode respectively. The N2790A, N2791A and ...
Page 3
... Frequency (Hz) Figure 4. Vout/Vin vs. frequency response of N2790A Figure 5. Frequency response (Vout/Vin) of N2790A when inputs are driven in common (common mode rejection) Figure 6. Input impedance vs. frequency of N2790A Vout Vout/Vin Vin BW (-3dB) = 147 MHz ...
Page 4
... Figure 7. Voltage derating curve of N2790A (voltage between either input and ground) Figure 8. Vout/Vin vs. frequency response of N2791A Figure 9. Frequency response (Vout/Vin) of N2791A when inputs are driven in common (common mode rejection) ...
Page 5
Figure 10. Input impedance vs. frequency of N2791A Figure 11. Voltage derating curve of N2791A (voltage between either input and ground) 5 ...
Page 6
Figure 12. Vout/Vin vs. Frequency response of N2891A at 1000:1 attenuation Figure 13. Frequency response (Vout/Vin) of N2891A when inputs are driven in common (common mode rejection) ...
Page 7
Figure 14. Input impedance vs. Frequency of N2891A Figure 15. Voltage derating curve of N2891A (voltage between either input and ground) 7 ...
Page 8
... Product number N2790A Bandwidth (-3dB) ≥100 MHz probe bandwidth* Rise time (calculated) ≤ 3.5 ns Attenuation 50:1 / 500:1 Gain accuracy (% of reading) ± 20-30ºC, ± 0-20ºC and 30-50ºC* DC CMRR - 500 VDC AC CMRR - 50/ kHz - MHz Propagation delay 14 nsec at 50:1, 12.8 nsec at 500:1 ...
Page 9
... Product number Description N2790A 100 MHz high-voltage differential probe N2790-68700 Probe tip accessory kit for N2790A including 2 each of browser tips, alligator plunger clips and pincer clips N2791A 25-MHz high-voltage differential probe N2791A-68700 Probe tip accessory kit for N2791A including 2 alligator clips ...
Page 10
... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2010 Printed in USA, November 25, 2010 5990-3780EN ...